ATM-TRK (Circuit Emulation Service Circuit Pack)
Table 10-104. ATM Board DSP Test (#1293) — Continued
Error
Test
Code
Result
2100
ABORT
2302
ABORT
2500
ABORT
2752
ABORT
XYZ
FAIL
XY8
PASS
0
NO
BOARD
555-233-123
Description/Recommendation
Could not allocate required system resources.
Inconsistent uplink message from the ATM-TRK circuit pack.
Internal system error
Retry the command up to 5 times at 1-minute intervals.
Circuit pack not a TN2305A/2306A.
There is at least one bad DSP on the board. The X value
indicates the number of bad talker DSPs, Y indicates the number
of bad listener DSPs and Z indicates the number of bad echo
canceler DSPs.
Test the Active Tone-Clock on the port network that contains the
ATM-TRK circuit pack for dial-tone. Repair as needed.
Repeat the short test on the ATM-TRK circuit pack.
If the test continues to fail, check for service-affecting MINOR
alarms. If a MINOR alarm is raised for Error Type 2817 or 1818,
replace the circuit pack.
If a WARNING alarm is raised, this is a non-service-affecting
error, and the circuit pack can still process calls.
The test passed for some or all DSPs. XY8 indicates the number
of talker, listener, and echo-canceler DSPs for which the test
passed (the rest of the DSPs were skipped). The X value
indicates the number of good talker DSPs, Y indicates the
number of good listener DSPs and Z indicates the number of
good echo canceler DSPs.
No board detected.
Check the Error Log for wrong board Error 125 (wrong board) or
Error 131 (no board). Replace or insert the circuit pack if
necessary.
Check that the board is properly translated and inserted.
If Error 1538 (hyperactivity) is listed in the Error Log, and run
reset board UUCSS.
Run the test again, and, if it fails, replace the ATM-TRK circuit
pack.
Retest.
Continued on next page