Maintenance Object Repair Procedures
Table 10-271. TEST #9 Digital Line NPE Crosstalk Test — Continued
Error
Code
1000
1001
1002
1003
10-726
Issue 4 May 2002
Test
Result
ABORT
System resources required to run this test are not available.
The port may be busy with a valid call. Use display port
PCSSpp to determine the station extension or attendant
number of the port. Use status station or status attendant to
determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before
retesting. Attendants are always in use (off-hook) if the handset
is plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at
1-minute intervals a maximum of 5 times.
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
ABORT
The system could not allocate time slots for the test. The
system is under heavy traffic conditions or has time slots
out-of-service due to TDM-BUS errors. Refer to TDM-BUS to
diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, repeat test at 1-minute intervals a maximum
of 5 times.
ABORT
The system could not allocate a tone receiver for the test. The
system is oversized for the number of Tone Detectors present,
or some Tone Detectors are out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to TTR documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to TONE-PT documentation.
3. If neither condition exists, retry the command at 1-minute
intervals a maximum of 5 times.
Description/Recommendation
Continued on next page