Maintenance Object Repair Procedures
Error Log Entries and Test to Clear Values
Table 10-177. Data Channel Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
(a)
0
Any
1
Any
Local Loop Back Test
(#111)
18
0
busyout data-module
ext
130
None
257
Any
Remote Maintenance
Looparound Test
(#109)
513
Any
Crosstalk Test (#110)
769
Any
Dual Port RAM Test
(#108)
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
a. Error Type 0: Switch has removed circuit pack has been removed or circuit
pack has been insane for more than 11 minutes.
1. Reinsert the circuit pack.
2. Verify that the alarm clears.
3. If problem persists, replace the circuit pack.
System Technician-Demanded Tests: Descriptions
and Error Codes
Two system technician test commands include the Data Channels (DATA-CHLs).
The test data-module ext [short | long] command tests the single
DATA-CHL, specified by ext.
The test network-control [short | long] command tests each
administered DATA-CHL that resides on the TN777B Netcon or
TN2401/TN794 NetPkt circuit pack in the specified carrier.
10-486
Issue 4 May 2002
Alarm
On/Off
Level
Board
Any
Any
MINOR
ON
WARNING
OFF
WARNING
ON
MINOR
ON
MINOR
ON
MINOR
ON
Test to Clear Value
test data-module ext sh r 1
test data-module ext sh r 3
release data-module ext
test data-module ext sh
test data-module ext sh r 5
test data-module ext sh r 3
test data-module ext l r 3
555-233-123