ANNOUNCE (Announce)
Table 10-55. Aux Data Error Codes and Recommended Repair Procedures
Aux
Data
32006
32007
32008
32009
32010
32013
32012
32014
555-233-123
— Continued
Description/Recommendation
Announcement Data Module not available.
1. Use the status command to check the status of the Announcement
Data Module.
Announcement Data Module out of service.
1. Use the status command to check the status of the Announcement
Data Module.
Announcement data is being saved or loaded.
1. Retry the command at two minute intervals a maximum of three times.
2. If the save/restore announcements command fails, escalate the
problem.
Required DATA-CHL is not administered or out of service. (A DATA-CHL is
required to save or restore announcements.)
1. Add a DATA-CHL if none is administered.
2. If a DATA-CHL is administered, use the status command to check the
status of all DATA-CHLs. At least one DATA-CHL should be in the
in-service/idle state.
DATA-CHL is not administered, or it is unavailable. (A DATA-CHL is
required to save or restore announcements.)
1. Add a DATA-CHL if none is administered.
2. If a DATA-CHL is administered, use the status command to check the
status of all DATA-CHLs. At least one DATA-CHL should be in the
in-service/idle state.
Required Announcement Data Module is not administered.
1. Add an Announcement Data Module and repeat the command.
Command timed out on the standby processor [286 systems]. This could
present problems.
1. Check the error and alarm logs for errors and alarms that are logged
against the STBY-SPE (Standby SPE) [286 systems].