Avaya Definity SI Maintenance Manual page 1082

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Table 10-118. BRI-SET/ASAI-ADJ Error Log Entries — Continued
Error
Aux
Associated
Type
Data
3584
0, 1
None
3585-
0
None
3839(i)
3840-
0
None
4095
(m) (n)
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2
Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
Notes:
a. Errors of this type indicate violations of the ISDN-BRI signaling protocol;
timers associated with certain Layer 3 messages have expired before a
required response was received. In the following table, the aux data field
indicates which timer has just expired. (For more information, refer to the
Avaya ISDN-BRI Specification.)
Aux Data
The switch sent a message to the endpoint which did not respond in the
allotted time. This can happen occasionally due to failure of the
point-to-point signaling link or because of a problem in the BRI endpoint or
10-296
Issue 4 May 2002
Alarm
Level
Test
BRI-PORT
2
First T303 (SETUP timer)
3
Second T303 (SETUP timer)
4
T305 (DISConnect timer)
5
First T308 (RELease timer)
6
Second T308 (RELease timer)
10
T316 (RESTart timer)
12
T309 (Layer 2 Failure timer)
16
TM100 (Management Information Message timer 1)
17
TM200 (Management Information Message timer 2)
102
TASAI (ASAI Routing Timer)
Alarm Level
ABRI-PORT
ATT-PORT
On/
LGATE-PORT
Off
ATTE-PT
Board
Continued on next page
Timer Type
Test to Clear Value
555-233-123

Advertisement

Table of Contents
loading