Maintenance Object Repair Procedures
Table 10-93. Error type 1281 Aux Data and repair procedures — Continued
Aux
Alarm
Data
Description
16
Loss of Signal:
LOS
17
Loss of Frame:
LOF
18
Multiplexer
Section Alarm
Indication Signal:
MS_AIS
19
Multiplexer
Section Remote
Defect Indicator:
MS_RDI
10-234
Issue 4 May 2002
Repair procedure
The fiber is not connected properly to the ATM-TRK board or ATM
switch (or to the multiplexer section [MUX] if present).It is possible
that the board transceivers are not functioning properly.
Run test board UUCSS command.
If Test #1259 fails with Error Code 16, connect a fiber back-to-back
in a looped mode (one strand of fiber connecting the transmit
transceiver to the receive transceiver of the board) and see if the
yellow LED flash goes away. If it does the problem is off-board.
If the yellow LED continues to flash, replace the circuit pack.
The fiber signal cannot obtain or maintain STM-1/OC-3 framing.
Try to more the fiber on the ATM switch side to a different port.
If the problem persists, reset the circuit pack (reset board UUCSS).
There is a major problem on the far end (between multiplexer
section [MUX] and the switch) that prohibits the circuit pack from
sending a valid signal.
See if the ports at the MUX and/or the ATM switch are connected
snugly.
Run test board UUCSS command
If Test #1259 fails with Error Code 18, connect a fiber back-to-back
in a looped mode (one strand of fiber connecting the transmit
transceiver to the receive transceiver of the board) and see if the
yellow LED flash goes away.
If it does the problem is off-board.
If the yellow LED continues to flash, replace the circuit pack; if the
error persists, escalate the problem.
The far-end is detecting a major problem with the signal that this
board is transmitting.
Make sure the ATM switch port (or a MUX port, if present between
ATM switch and the ATM-TRK board) is the same as the ATM-TRK
circuit pack's cable interface
Run test board UUCSS command.
If Test #1259 fails with Error Code 19, connect a fiber back-to-back
in a looped mode (one strand of fiber connecting the transmit
transceiver to the receive transceiver of the board) and see if the
yellow LED flash goes away.
If it does the problem is off-board.
If the yellow LED continues to flash, replace the circuit pack; if the
error persists, escalate the problem.