Avaya Definity SI Maintenance Manual page 1267

Table of Contents

Advertisement

DATA-BD (Data Channel NetPkt Circuit Pack)
Error Log Entries and Test to Clear Values
Table 10-174. Data Channel Processor Circuit Pack Error Log entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1 (a)
0
Data Channel
Reset Test (#107)
23 (b)
0
None
257
Any
Control Channel
Test (#52)
257 (c)
0
None
513 (d)
Any
None
769 (e)
4358
None
1025 (f)
4363
NPE Audit Test
(#50)
1538 (g)
Data Channel
Reset Test (#107)
3840 (h)
Any
None
3999(i)
Any
None
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Notes:
a. Error Type 1: DATA-BD portion of the TN2401/TN794 NetPkt or TN777B
Netcon circuit pack not functioning.
Cannot reset TN2401/TN794 NetPkt or TN777B Netcon circuit pack with
usual command (reset board PCSS). Use Data Channel Reset Test
(#107) in the Long Test Sequence for the DATA-CHLs to reset.
1. Determine how many Data Channels (DATA-CHLs) are
2. Administer a DATA-CHL as necessary (add data-module [
3. Select a Data Channel (DATA-CHL) from the list (list data).
555-233-123
Alarm
Level
Any
MINOR
WNG
MINOR
MINOR
administered (list data).
NOTE:
A Data Channel (DATA-CHL) is identified by a "type" value of
"netcon."
next]).
On/Off
Board
Test to Clear Value
Any
test data-module ext sh r 1
ON
test data-module ext l
OFF
ON
test network-control [a | b] sh r
20
test network-control [a | b] sh
ON
test data-module ext l
Continued on next page
Issue 4 May 2002
|
ext
10-481