ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon
Analog Line)
Station Status and Translation Audits and
Updates Test (#36)
This test updates the analog port's message lamp state (if it has one) and
translations (such as station type, dial type, network connection) with information
kept in the software. The software is updated with the switchhook state reported
by the port processor. When the ringer is in the off state, this test also turns off the
station's ringer to prevent constant ringing caused by defective hardware.
Table 10-34. TEST #36 Station Status and Translation Audits and Updates Test
Error
Code
1004
1005
555-233-123
Test
Result
ABORT
Could not allocate the necessary system resources to run this
test.
ABORT
System resources required to run this test are not available.
The port may be busy with a valid call. Use the display port
PCSSpp command to determine the station extension. Use the
status station command to determine the service state of the
port. If the service state indicates that the port is in use, then
the port is unavailable for certain tests. You must wait until the
port is idle before retesting.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
ABORT
The test was aborted due to a configuration problem. This
code will result under either of the following conditions:
1. This test may not be applicable, or it may be disruptive to
terminal equipment other than a voice terminal (for
example, the modem pool member or music on hold).
2. The circuit pack is one of the following:
— TN742 vintages 13,14 and 15
— TN769 vintages 3,4 and 5
Description/Recommendation
Continued on next page