Avaya Definity SI Maintenance Manual page 1226

Table of Contents

Advertisement

Maintenance Object Repair Procedures
Table 10-163. CO Trunk Error Log Entries — Continued
Error
Aux
Type
Data
2049
NPE Cross Talk Test
(#6)
2561 (d)
57345
None
2817 (a)
57360
None
2817 (a)
57393
None
2817 (d)
57484
Dial Tone Test (#0)
3073 (d)
57376
None
3329 (d)
57408
None
3329 (d)
57484
Dial Tone Test (#0)
3585 (d)
57424
None
3840 (f)
8000
Analog Transmission
(#844-848)
3841 (f)
Analog Transmission
(#844-848)
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2
Minor alarms on this MO may be downgraded to warning alarms based on the values used in the set
options command. If the Minor alarm is not downgraded by the set-options values, the Minor alarm
is upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
Notes:
a. These are in-line errors that have no specific test associated with them.
b. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate associated
errors (if any).
c. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
d. Aux data 57345 -- Single polarity ringing current
Aux data 57376 -- No loop current on incoming call
Aux data 57408 -- No tip ground detected on outgoing call
Aux data 57424 -- No loop current on outgoing call
Aux data 57484 -- No dial tone on outgoing call
10-440
Issue 4 May 2002
Alarm
Associated Test
Level
MAJ/MIN/
WRN
MAJ/MIN/
WRN
MAJ/MIN/
WRN
MINOR
On/
Off
Board
Test to Clear Value
ON
test port PCSS l r 3
2
OFF
test port PCSS l r 1
2
OFF
test port PCSS l r 1
2
OFF
OFF
test analog testcall UUCSS
pp r 2
Continued on next page