MP
Function and input
MP7690
MEMORY TEST during switch-on
Format:
Input:

4.3.18 Second Spindle

MP
Function and input
MP13010 to
Machine parameter block for the second spindle
MP13520
Input:
December 2001
Bit 5 – AUTOSTART soft key
0: Do not display soft key
1: Display soft key
Bit 6 – Display of pallet table and NC program
0: Both simultaneously in a split screen
1: Pallet table or NC program individually
Bit 7 – AUTOSTART function by PLC
0: AUTOSTART function performed by the NC
1: AUTOSTART function of an NC program is
performed by the PLC. The NC does not trigger
an NC start.
%xxx
1: No MEMORY TEST during switch-on
0: MEMORY TEST during switch-on
Bit 0 – Test the RAM
Bit 1 – Test the EPROM
Bit 2 – Test the hard disk
Function and input range are identical with
MP3010 to MP3520.