MP
Function and input
MP910.0-8
Positive software limit switches, traverse range 1 (default
setting after power on)
Input:
MP911.0-8
Positive software limit switches, traverse range 2
Input:
MP912.0-8
Positive software limit switches, traverse range 3
Input:
MP920.0-8
Negative software limit switches, traverse range 1 (default
setting after power on)
Input:
MP921.0-8
Negative software limit switches, traverse range 2
Input:
MP922.0-8
Negative software limit switches, traverse range 3
Input:
MP950.0-8
Datum for positioning blocks with M92 for axes 1 to 9
Input:
MP951.0-8
Simulating tool change position for TOOL-CALL during
block scan for axes 1 to 9
Input:
MP960.0-8
Machine datum for axes 1 to 9
Input:
4 – 18
-99 999.9999 to +99 999 [mm] or [°]
-99 999.9999 to +99 999 [mm] or [°]
-99 999.9999 to +99 999 [mm] or [°]
-99 999.9999 to +99 999 [mm] or [°]
-99 999.9999 to +99 999 [mm] or [°]
-99 999.9999 to +99 999 [mm] or [°]
-99 999.9999 to +99 999.9999 [mm] or [°]
Values with respect to the machine datum
-99 999.9999 to +99 999.9999 [mm] or [°]
-99 999.9999 to +99 999.999 [mm] or [°]
Values with respect to the scale reference point
HEIDENHAIN Technical Manual TNC 426, TNC 430
Software
Page
version and
behavior
PLC
6 – 25
PLC
6 – 25
PLC
6 – 25
PLC
6 – 25
PLC
6 – 25
PLC
6 – 25
PLC
6 – 224
RUN
PLC
6 – 295
RUN
PLC
6 – 102,
6 – 224
REF