3.5.4 Adapters for Encoder Signals
3 – 40
Encoder signals with 11 µA
interface with HEIDENHAIN adapter connectors.
Note
Please note:
n
The adapters adjust only the levels, not the signal shape.
n
The contamination signal of the square-wave encoder cannot be
evaluated.
n
A square-wave signal can be subdivided no more than 4-fold.
or TTL levels can be adapted to the 1 V
PP
HEIDENHAIN Technical Manual TNC 426, TNC 430
PP