TEXTFILE=<fname>
Links a text file into the PLC window. The text begins at the current position.
Every additional line begins at the same X position, but offset downward by
LINEDIST. The line break automatically adapts to the available space.
Characters such as "Line Feed," "Carriage Return," "Horizontal Tab,"
"Vertical Tab" are converted to spaces.
The backslash "\" is used as a special symbol. It can therefore execute the
following functions:
"\n", "\N"
Insert manual line feed (end of paragraph).
"\f", "\F"
Insert page feed (division into more than one screen page).
„\\"
Shows the "\" character in the text.
<fname>
Contains a file name with path, or the file name only. In this case the path in
MP7230.3 is added (language for help files).
ERRQUE=n [/c] [/e] [/l] [/n] [/s]
Links a table with the messages waiting in the PLC error queue.
n: Number of table lines
/c: Table is updated cyclically.
/e: Paging in tables, message can be acknowledged with CE.
/l: Alternative to /n . Error number before the error text. Position in the error
queue is displayed.
/n: Alternative to /l. /l has priority.
Error number before the error text.
Line number of the .PET table is displayed.
/s: Three-digit status field with the following information:
C: CE possible
S: Message causes a stop
E: Message causes an EMERGENCY STOP
F: Resets the feed-rate enabling
0 to 2: Priority
REFRESH=n
Time interval in [ms]
All variables with the /c switch are checked and, if required, redisplayed.
Value range: 100 to 100 000 [ms]
Default setting: 400 ms
KBD
This command is needed only if relatively long texts are to be moved with the
cursor keys. It assigns the keyboard to the PLC window as long as it is visible
on the screen.
If the page limits were defined with \f, it is possible to scroll and to page up
and down with the arrow keys.
If the mask contains elements with the /e or /i switch, the keyboard is
automatically assigned to the PLC window. In this case the arrow keys jump
from input field to input field.
Soft keys, screen switch-over keys, operating mode keys, special function
keys (MODE, PGM-MGT, CALC) always remain assigned to the NC.