December 2001
7 7 7 7
Enter the following test program:
LBL 1
L X <maximum traverse>
R0 FMAX
LX0 FMAX
CALL LBL1 REP 100/100
7 7 7 7
Display the actual speed (act. speed) with the integrated oscilloscope and,
if necessary, also show the following error (lag).
7 7 7 7
Start the test program with feed rate override = 100%.
7 7 7 7
In MP1090.0 increase the jerk until the overshoot just disappears.
MP1090 optimum
MP1090 too large
Commissioning
6 – 485