Module 9310 Read the machine parameter from the run-time memory

With this module you can read the value of the given machine parameter from
the run-time memory. The input value is transferred as a natural number with
the decimal point shifted by the number of possible decimal places.
A value is read from the run-time memory.
For non-indexed machine parameters, zero must be transferred as the index.
Call:
PS
B/W/D/K <MP number>
PS
B/W/D/K <MP index>
CM
9310
PL
B/W/D
<MP value / Error code>
1: MP number does not exist
6: Call was not in a submit or spawn job
7: MP is of the "string" type
8: No system memory
Error recognition:
Marker
Value
Meaning
M4203
0
MP was read
1
Error code in W1022
W1022
20
Module was not called in a spawn job or submit job