MP
Function and input
MP1150
Delay time for erasing the nominal velocity value with the
erasable error message: EXCESSIVE SERVO LAG IN <AXIS>
Input:
MP1150.0
Delay time for erasing the nominal velocity value with the
erasable error message: EXCESSIVE SERVO LAG IN <AXIS>
Input:
MP1150.1
Time period for which the monitoring function is to remain
off after the fast PLC input defined in MP4130.0 is set.
Input:
MP1150.2
Minimum time period for which the monitoring functions
are to remain effective after expiration of the time from
MP1150.1.
Input:
MP1152
Interrogation of I3 "Control-is-ready signal
acknowledgement"
Input:
MP1220
Analog axes: automatic cyclic offset adjustment
Input:
MP1320
Direction for traversing the reference marks
Format:
Input:
MP1330.0-8
Velocity for traversing the reference marks for axes 1 to 9
Input:
MP1331.0-8
Velocity for leaving the reference mark end position for axes
1 to 9 (only for rotary encoders MP1350 = 2)
Input:
December 2001
0 to 65.535 [s]
Recommended: 0 s
0 to 65.535 [s] Recommended: 0
0 to 65.535 [s]
0: Monitoring functions off
Recommended: 0.2 to 0.5
0 to 65.535 [s]
0: I3 is passed on directly to the NC
1: I3 is processed by the PLC before being
passed on to the NC
0 to 65 536 [s]
0: No automatic adjustment
%xxxxxxxxx
Bits 0 to 8 correspond to axes 1 to 9
0: Positive
1: Negative
80 to 300 000 [mm/min]
10 to 300 000 [mm/min]
List of Machine Parameters
Software
Page
version and
behavior
PLC
6 – 130,
6 – 157,
RUN
6 – 160
280 476-01
280 476-21
6 – 173
from
6 – 151
280 474-07
no longer
PLC
RUN
PLC
6 – 102
PLC
6 – 102
RUN
PLC
6 – 102
RUN