7.7.16 RESET (R)

Function
Load the operand
content into the logic
accumulator.
Gate the content of
the logic
accumulator and
input I5 with OR
Since the result of
the operation is 1,
reset output O2.
Since the result of
the operation is 1,
reset marker M500.
December 2001
Syntax:
R (RESET)
Operands:
M, I, O, T, C
Action:
If the logic accumulator = 1, then set the addressed operand to 0, otherwise
do not change it. Use the R command at the end of a sequence of logical
gating operations in order to influence an operand independently from the
result of gating. This command can be used several times in succession (see
example).
Example:
Gate input I4 and I5 with OR. If the gating result is 1, then reset output O2 and
marker M500.
Initial state:
Input
I4
= 1
Input
I5
= 0
Output
O2
= ?
Marker
M500 = ?
STL
Accumulator contents [bit]
31..15 ..................... 7 ................. 0
L I4
x ..... x x x x x x x x 1 x x x x x x x
O I5
x ..... x x x x x x x x 1 x x x x x x x
R O2
x ..... x x x x x x x x 1 x x x x x x x
R M500
x ..... x x x x x x x x 1 x x x x x x x
Commands