Module 9153 Switching The Touch Probe Axis - HEIDENHAIN TNC 426 PB/M Technical Manual

Table of Contents

Advertisement

6 – 350
MP6161
M function for orienting the touch probe before every
measuring process
Input:
–1: Spindle orientation directly through NC
0: Function inactive
1 to 999: Number of the M function
MP6162
Orientation angle
Input:
0 to 359.9999 [°]
MP6163
Minimum difference between the current spindle angle and
MP6162 before executing an oriented spindle stop
Input:
0 to 3.0000 [°]
MP6165
Orient the probe before approaching with Cycle 0 or 1, or
with manual probing
Input:
0: Probe is not oriented before each probing
1: Probe is oriented and always deflected in the same direction
MP6361
Rapid traverse in probing cycle (measuring touch probe)
Input:
10 to 10 000 [mm/min]
MP7411
Tool data in the touch probe block
Format:
%xx
Input:
Bit 0 –
0: Use the calibrated data of the touch probe
1: Use the current tool data from the last TOOL CALL
Bit 1 –
0: Only one set of touch probe calibration data
1: Use the tool table to manage more than one set of touch
probe calibration data
MP7490
Functions for traverse ranges
Format:
%xxxx
Input:
Bit 2 – Calibration data: touch probe for workpiece
measurement:
0: One set of calibration data for all traverse ranges
1: Every traverse range has its own set of calibration data

Module 9153 Switching the touch probe axis

Specify a new touch probe axis (axis 0, 1 or 2) for manual measurement. A
new touch probe axis can be specified only if MP7490 bit 2 = 1.
Call:
PS
B/W/D/K <Axis number 0 to 2>
CM
9153
Error recognition:
Marker
Value
Meaning
M4203
0
No error
1
Error code in W1022
W1022
2
Invalid axis number
20
Module was not called in a spawn job or submit job
HEIDENHAIN Technical Manual TNC 426, TNC 430

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tnc 430 pa/mTnc 430 mTnc 426 cbTnc 430 caTnc 426 pbTnc 430 pa ... Show all