HEIDENHAIN TNC 426 PB/M Technical Manual page 546

Table of Contents

Advertisement

6 – 216
PWM output of the second spindle Machine parameters of the second
X51
X52
X53
X54
X55
X56
X57
X58
X59
Note
Axis-specific parameters must be set to zero. Machine parameters that are
available for the first spindle may not be available for a second spindle.
MP4020
PLC compatibility
Format:
%xxxxxxxx
Input:
Bit 5 — Single- or double-spindle operation
0: Single-spindle operation
1: Double-spindle operation
Module 9175 Spindle switchover
With this module you can switch between spindle 1 and spindle 2. When
switching via an M strobe, MP7440 bit 2 must not be set. When switching via
an S or G strobe, MP3030 or MP13030, respectively, must not be set. The
module only needs to be called once.
Call:
PS
B/W/D/K <Spindle number>
0: First spindle
1: Second spindle
CM
9175
Error recognition:
Marker
Value
Meaning
M4203
0
Specified spindle active
1
Error code in W1022
W1022
2
Invalid spindle number
6
M4157 = 1 (RESTORE POSITION active)
20
Module was called in a spawn job or submit job
21
Missing strobe in M4176 = 1
MP13010 to MP13520 Machine parameter block for the second spindle
Input:
Function and input range are identical to MP3010 to MP3520
spindle
MP2020.0 to MP2930.0
MP2020.1 to MP2930.1
MP2020.2 to MP2930.2
MP2020.3 to MP2930.3
MP2020.4 to MP2930.4
MP2020.5 to MP2930.5
MP2020.6 to MP2930.6
MP2020.7 to MP2930.7
MP2020.8 to MP2930.8
HEIDENHAIN Technical Manual TNC 426, TNC 430