24 Vdc Switching Input/Outputs; Diagnosis Of The Pl - HEIDENHAIN TNC 426 PB/M Technical Manual

Table of Contents

Advertisement

Diagnosis of the PL

6.17.1 24 Vdc Switching Input/Outputs

December 2001
Module 9007 Diagnostic information of the PL
Module 9007 can ascertain diagnostic information on the PL 4xxB. To save
computing time, refrain from continuously calling this module.
Call:
PS
B/W/D/K <Number of the logical PL>
PS
B/W/D/K <Number of the information>
0: Readiness
1: Supply voltage
Bit 0: Logic voltages 24 V and 5 V
Bits 1 to 4: 24 V for X11 to X14
Bit 5: 24 V for analog inputs
2: Analog inputs used
3: Total number of PLs on this LE
4: Further PLs on this PL?
5: PL is a PL 410 B
CM
9007
PL
B/W/D/K <Diagnostic information>
0: Not available
1: Available
0 to 4: Number of PLs
Error recognition:
Marker
Value
Meaning
M4203
0
Diagnostic information was read
1
Error code in W1022
W1022
1
Invalid code
2
Invalid PL
24
Module was called in a spawn job or submit job
The current conditions of the switching inputs and outputs are available for
you in PLC addresses
(See "Mounting and Electrical Installation" on page 3 – 5).
For the current states of the inputs/outputs of the PLC:
7 7 7 7
Read all inputs with Module 9002.
7 7 7 7
Or only certain inputs with Module 9008.
7 7 7 7
Update all outputs with Module 9005.
7 7 7 7
Or only certain outputs with Module 9009.
PLC Inputs/Outputs
6 – 389