Module 9215 uses the following events:
n
$01 000 000 Window build-up
n
$00 010 000 Closing the pop-up window
The event for window build-up is generated internally and must not be started
externally. If the event for closing the pop-up window is transferred, the
module closes without waiting for keyboard input.
Module 9215 Activating a PLC pop-up window
Call only in a submit job.
Call:
PS B/W/D/K/S
<String with window heading>
PS B/W/D/K/S
<String with file name of the list>
[complete path or only file name]
PS B/W/D/K
<Start position>
[line in which the highlight is located]
PS B/W/D/K
<Mode>
Bit 0/Bit 1 – Character size
00: Automatic
01: Small character
10: Medium character
11: Large character
Bit 2 – Frame
0: With frame
1: Without frame
Bit 3 – Heading
0: Display heading
1: Do not display heading
Bit 4 – Positioning error
0: No hot keys
1: Hot keys (0 to 9 and A to Z) before menu items
Bit 5 – Vertical / Horizontal
0: Vertical arrangement
1: Horizontal arrangement (bit 4 = 0)
CM 9215
PL B/W/D
<Selected line>
0 to n: Line number from list
–1: No selection made (END, NOENT)
2: For error see W1022
Error recognition:
Marker
Value
Meaning
M1022
0
Incorrect mode transferred
3
Not a valid string for file name or heading
6
Window cannot be displayed (internal error, e.g.
problems with memory or operating system)
20
Module was not called in a spawn job
28
Another PLC pop-up window is open
36
File with the list could not be found