Probing from OEM
cycles
December 2001
7 7 7 7
With FN17:SYSWRITE ID990 NR1, adjust the approach behavior. If the input
value = 0, the setup clearance from MP6140 and the effective radius are
accounted for. If the input value > 0, the workpiece is approached as if the
effective radius and setup clearance were zero. This function can be used,
for example, for measuring small holes.
If you use the TS 632 infrared touch probe, you must orient the touch probe
before the measuring process in order to align the touch probe and the
receiver unit. Define an M function for automatically orienting the probe to a
specific position before probing. If the ready signal of the touch probe is
already available, the touch probe is not oriented.
7 7 7 7
In MP6161, enter the number of the M function.
7 7 7 7
Enter the orientation angle in MP6162.
7 7 7 7
In MP6163, enter a minimum angle difference for orienting with the defined
M function.
M4050
Touch probe not ready, ready signal
is missing
M4051
Stylus deflected before start of
probing cycle
M4052
Stylus is deflected, probing process
is completed
M4053
Probing process has been ended or
canceled
M4054
Battery voltage too low (battery
warning at touch probe connection);
evaluated only during the probing
process
M4055
Enable the probing process
M4056
NC stop in all operating modes if
stylus is deflected
M4574
Select the traverse range (with
M4575)
M4575
Select the traverse range (with
M4574)
Orient when MP6163 < current spindle angle MP6162
MP6120
Probing feed rate (triggering touch probe)
Input:
1 to 3000 [mm/min]
MP6360
Probing feed rate (measuring touch probe)
Input:
1 to 3000 [mm/min]
MP6130
Maximum measuring range
Input:
0.001 to 99 999.9999 [mm]
MP6140
Setup clearance over measuring point
Input:
0.001 to 99 999.9999 [mm]
MP6150
Rapid traverse in probing cycle (triggering touch probe)
Input:
10 to 20 000 [mm/min]
Touch Probe
Set
NC
NC
NC
NC
NC
NC
PLC
PLC
PLC
(
Reset
NC
NC
PLC
NC
NC
PLC
PLC
PLC
PLC
)
6 – 349