Operating Times - HEIDENHAIN TNC 426 PB/M Technical Manual

Table of Contents

Advertisement

6.13.31 Operating Times

6 – 328
The TNC can measure up to 11 operating times and store them in a file in the
SYS partition:
Operating time
TNCTIME
MACHINETIME
PROGTIME
PLCTIME0 to PLCTIME7
For all operating modes except PROGRAMMING AND EDITING: The
operating times are displayed in the MOD function "Machine Time":
7 7 7 7
Press the MOD key and press the MACHINE TIME soft key.
7 7 7 7
With MP7237.x, specify the times that can be reset with the code number
857282, and the PLC operating times that you wish to display.
7 7 7 7
In MP7238.x, define the dialog messages to be displayed for the individual
operating times.
The time is measured in seconds and is updated every minute during the run
time. When the control is switched off, no more than one minute is lost.
The NC measures the time for TNCTIME, MACHINETIME and PROGTIME.
For the operating times PLCTIME0 to PLCTIME7:
7 7 7 7
Start with Module 9190.
7 7 7 7
Stop with Module 9191.
Except for TNCTIME, all operating times are saved during a hard-disk backup
with the program TNCBACK (See "NC Software Exchange" on page 2 – 33).
With the following modules you can evaluate and change the operating times:
n
Module 9190: Starting the operating times
n
Module 9191: Stopping the operating times
n
Module 9192: Reading the operating times
n
Module 9193: Setting the operating times
n
Module 9194: Alarm when operating times are exceeded
Meaning
Control on
Machine on
Program run
Definable times of the PLC
HEIDENHAIN Technical Manual TNC 426, TNC 430