Module 9055 Local Time - HEIDENHAIN TNC 426 PB/M Technical Manual

Table of Contents

Advertisement

6 – 332

Module 9055 Local time

With Module 9055 you can convert the value read with Module 9195 into a
legible ASCII format. Module 9055 corrects the transferred value by the
difference to local time as entered in MP7235.
Call:
PS
B/W/D/K <System time>
Number of seconds since 0:00 hours on January 1, 1970.
PS
B/W/D/K <String number>
0 to 7
PS
B/W/D/K <Format>
0: DD.MM.YYYY hh:mm:ss
1: D.MM.YYYY h:mm:ss
2: D.MM.YYYY h:mm
3: D.MM.YY h:mm
4: YYYY-MM-DD- hh:mm:ss
5: YYYY-MM-DD- hh:mm
6: YYYY-MM-DD h:mm
7: YY-MM-DD- h:mm
8: DD.MM.YYYY
9: D.MM.YYYY
10: D.MM.YY
11: YYYY-MM-DD
12: YY-MM-DD
13: hh:mm:ss
14: h:mm:ss
15: h:mm
CM
9055
Error recognition:
Marker
Value
Meaning
M4203
0
String was generated
1
Incorrect transfer value
MP7235
Time difference to Universal Time (Greenwich Mean Time)
Input:
–23 to +23 [hours]
0: Universal Time (Greenwich Mean Time)
1: Central European Time (CET)
2: Central European daylight-saving time
HEIDENHAIN Technical Manual TNC 426, TNC 430