3.10 Data Interface

3.10.1 RS-232-C/V.24 Data Interface

X21: RS-232-C/V.24
data interface
Logic unit
Connecting cable
Id. Nr. 239 760-xx
D-sub
Assign-
D-sub
cnnctr.
ment
cnnctr.
(female)
(male)
25-pin
25-pin
1
GND
1
2
RXD
2
3
TXD
3
4
CTS
4
5
RTS
5
6
DTR
6
7
Signal
7
GND
20
DSR
20
8 to 19,
Do not
21 to 25
assign
Housing Ext.
Housing Ext.
shield
3 – 60
The TNC features three interfaces:
n
RS-232-C/V.24
n
RS-422/V.11
n
Ethernet connection
The interfaces can be used simultaneously. The user selects the interfaces he
wishes to use. (See "Data Interfaces" on page 8 – 3).
Please note:
n
Maximum cable length 20 m.
n
To connect a peripheral device you must install an adapter cable either in the
electrical cabinet or on the operating panel. See also "Dimensions" at the
end of this chapter.
n
For connecting cables, see "Cable Overview" at the end of this chapter.
Pin layouts on logic unit, connecting cables, and adapter block:
Note
The interface complies with the requirements of EN 50 178 for "low
voltage electrical separation."
D-sub
cnnctr.
(female)
25-pin
WH/BN
1
Ext.
shield
Green
3
Yellow
2
Gray
5
Pink
4
Blue
20
Red
7
Brown
6
8
Housing
shield
AB
Connecting cable
Id. Nr. 310 085-01
Id. Nr. 274 545-01
D-sub
D-sub
D-sub
cnnctr.
cnnctr.
cnnctr.
(male)
(female)
(male)
25-pin
25-pin
25-pin
1
1
1
3
3
3
2
2
2
5
5
5
4
4
4
20
20
20
7
7
7
6
6
6
8
8
8
Housing Housing
Housing Ext.
HEIDENHAIN Technical Manual TNC 426, TNC 430
D-sub
cnnctr.
(female)
25-pin
WH/BN
1
External
shield
Yellow
2
Green
3
Pink
4
Gray
5
Brown
6
Red
7
Blue
20
8
Housing
shield

Advertisement