HEIDENHAIN TNC 426 PB/M Technical Manual page 619

Table of Contents

Advertisement

December 2001
n
EMER.STOP
0: No EMERGENCY STOP upon activation of the error message
1: EMERGENCY STOP upon activation of the error message
n
CE
0: Error message can be cleared with the CE key
1: Error message cannot be cleared with the CE key
n
PRIOR
A priority of 0 to 2 can be entered for the error message. Priority 0 is the
highest. The active PLC error messages are displayed in order of priority.
Module 9085 Display PLC error messages
Up to 32 error message can be placed in the queue, of which up to eight can
be from the string memory.
Blinking error message: Is displayed without entry in the queue.
Error number –1: Blinking error message EMERGENCY STOP PLC is displayed,
even if no .PET table was defined.
Error number not equal to –1 and no .PET table selected:
Blinking error message PLC: NO ERROR TABLE SELECTED
Call:
PS B/W/D/K
<Line no. .PET table>
0 to 999: Line number
–1: Blinking error message EMERGENCY STOP PLC
CM 9085
Error recognition:
Marker
Value
Meaning
M4203
0
Error message displayed or in queue
1
Error code in W1022
W1022
1
Line number not available
8
Incorrect operating mode, error marker compatibility
set
23
Overflow of PLC error message queue, or too many
error messages from string memory
Display and Operation
6 – 289

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tnc 430 pa/mTnc 430 mTnc 426 cbTnc 430 caTnc 426 pbTnc 430 pa ... Show all

Table of Contents