Module 9270: Reading A Code Word; Module 9271: Writing A Code Word - HEIDENHAIN TNC 426 PB/M Technical Manual

Table of Contents

Advertisement

December 2001

Module 9270: Reading a code word

With Module 9270 you can read an entry from the OEM.SYS file.
Call:
PS
B/W/D/K/S<String with code word>
PS
B/W/D/K <String number for result [0 to 7]>
CM
9270
Error recognition:
Marker
Value
Meaning
M4203
0
Interface was released
1
Error. See W1022.
W1022
3
Not a valid string for code word or result
12
String for code word is too long
20
Module was not called in a spawn job or submit job
30
Code word was not found

Module 9271: Writing a code word

With Module 9271 you can write an entry into the OEM.SYS file.
Call:
PS
B/W/D/K/S<String with code word>
PS
B/W/D/K <String number for result [0 to 3]>
CM
9271
Error recognition:
Marker
Value
Meaning
M4203
0
Interface was released
1
Error. See W1022.
W1022
3
Entry was written
6
PLCMAIN or MPFILE was transferred
12
String for code word is too long
30
Module was not called in a spawn job or submit job
Hard-Disk Organization
7 – 43

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tnc 430 pa/mTnc 430 mTnc 426 cbTnc 430 caTnc 426 pbTnc 430 pa ... Show all

Table of Contents