Connecting The Pl 4Xxb Input/Output Unit - HEIDENHAIN TNC 426 PB/M Technical Manual

Table of Contents

Advertisement

3.16 Connecting the PL 4xxB Input/Output Unit

Device
Id. Nr.
PL 410B
263 371-xx
PL 410B
263 371-xx
PL 405B
263 371-xx
December 2001
Up to four PL 4xxB can be connected to the TNC.
TNC 426 CB, TNC 430 CA:
One PL can be mounted in the logic unit, additional PLs are mounted in the
electrical cabinet.
TNC 426 PB/M, TNC 430 PA/M:
The PLs must be mounted separately in the electrical cabinet.
The PL 410B is available with and without analog inputs.
Switching
Switching
inputs
outpt.
24 Vdc
24 Vdc
64
31
64
31
32
15
No more than one PL 405B may be used. If connecting through PL 410B, the
PL 405B must be connected last.
Connecting the PL 4xxB Input/Output Unit
Analog inputs
Inputs for Pt 100
(±10 V)
thermistors
4
4
3 – 83

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tnc 430 pa/mTnc 430 mTnc 426 cbTnc 430 caTnc 426 pbTnc 430 pa ... Show all

Table of Contents