Operating A Second Spindle; Assignment Of Encoder Input And Speed Command Output; Switching Between The Spindles; Commissioning The Second Spindle - HEIDENHAIN TNC 426 PB/M Technical Manual

Table of Contents

Advertisement

6.12.14 Operating a Second Spindle

Assignment of
encoder input and
speed command
output
Switching between
the spindles
Commissioning the
second spindle
December 2001
With the TNC you can operate two spindles alternately, i.e., only one spindle
can be active at a given time. The TNC provides digital and analog speed
command signals for both spindles.
The following combinations of speed command signals are available for the
two spindles:
Operation of the first spindle
Digital
(TNC without integral spindle DSP)
Digital
(TNC with integral spindle DSP)
Analog
(TNC with and w/o integral spindle DSP)
The second spindle is driven instead of an axis, i.e., there are fewer axes
available. An exception is analog operation of the second spindle without a
position encoder. In this case all axes remain available. The assignment of
position and speed encoder inputs as well as of speed command outputs is
entered in MP111.x, MP113.x and MP121.x
(See "Assignment" on page 6 – 15).
Note
If the speed encoder (with active reference mark monitoring, MP2221 bit
0) of a spindle with integral spindle DSP is disconnected and reconnected,
the reference mark must be reevaluated (M4015) after the drive has been
switched on again, otherwise the error message Incorrect reference
position appears.
You can switch between the two spindles through the PLC:
7 7 7 7
Enter MP4020 bit 5 = 1 to activate double spindle operation.
7 7 7 7
With Module 9175, switch between spindle 1 and spindle 2.
7 7 7 7
Digital second spindle: In MP10, deactivate one axis.
7 7 7 7
Digital second spindle: Set MP110.x, MP112.x and MP120.x of the
deactivated axis to zero.
7 7 7 7
Machine parameters MP13010 to MP13520 are available for the second
spindle. In their functions and input ranges, these parameters are identical
with MP3010 to MP3520 for the first spindle.
(See "Spindle" on page 6 – 180)
7 7 7 7
Current and speed controller: For commissioning, use the machine
parameters MP2020.x to MP2930.x. The index x depends on the PWM
output in use; see also the following table.
Operation of the second
spindle
Analog
Digital or analog
Analog
Spindle
6 – 215