Clearing The Status Display - HEIDENHAIN TNC 426 PB/M Technical Manual

Table of Contents

Advertisement

Clearing the status
display
December 2001
To erase the status display, tool data and contents of the Q parameters:
7 7 7 7
Select the conditions with MP7300. All programmed values in the status
display, such as scaling factor, datum shift, and feed rate are reset. The
Q parameters and tool data are set to zero.
MP7300
Erasing the status display and Q parameters
Input:
0: Erase the status display, Q parameters and tool data when a
program is selected.
1: Erase the status display, Q parameters and tool data if a
program is selected and M02, M30, and END PGM occur.
2: Erase the status display and tool data when a program is
selected.
3: Erase the status display and tool data when a program is
selected and in the event of M02, M30, END PGM.
4: Erase the status display and Q parameters when a program
is selected.
5: Erase the status display and Q parameters when a program
is selected and in the event of M02, M30, END PGM.
6: Erase the status display when a program is selected and in
the event of M02, M30, END PGM.
7: Erase the status display when a program is selected and in
the event of M02, M30, END PGM.
Input
Erase with
PGM MGT
0
x
1
x
2
x
3
x
4
x
5
x
6
x
7
x
Display and Operation
Erase with
Status
M02, M30,
display
END PGM
x
x
x
x
x
x
x
x
x
x
x
x
Tool data
Q para-
meters
x
x
x
x
x
x
x
x
6 – 241