Equal To (==) - HEIDENHAIN TNC 426 PB/M Technical Manual

Table of Contents

Advertisement

7.7.32 EQUAL TO (==)

Function
Load the constant
into the word
accumulator.
Gate the content of
the word
accumulator with the
operand content D8;
if not equal, set the
logic accumulator to
0.
Assign the result to
marker M500.
7 – 120
Syntax:
== (EQUAL)
Operands:
B, W, D, K
Action:
This command sets off a direct transition from word to logical processing.
Gate the content of the word accumulator with the content of the addressed
operand. If the word accumulator and the operand are equal, the condition is
true and the TNC sets the logic accumulator to 1. If they are not equal, the
logic accumulator is set to 0. The comparison takes place over the number of
bits corresponding to the operand,
where B = 8 bits, W = 16 bits, and D = K = 32 bits.
Example:
Compare a constant with the content of double word D8, and assign the result
to marker M500.
Initial state:
Constant
= 16 000 (dec)
Double word D8
= 15 000 (dec)
Marker
M300 = ?
To improve clarity, the contents of the accumulator and operand are shown in
decimal notation. The ten-digit accumulator results from the greatest possible
accumulator content (2 147 483 647).
STL
Accumulator contents (dec or [bit])
x
L
K16000
31..15 ..................... 7 .................. 0
== D8
x ..... x x x x x x x x 0 x x x x x x x
= M500 x ..... x x x x x x x x 0 x x x x x x x
x x x
x x x
x x x
1 6
0 0 0
HEIDENHAIN Technical Manual TNC 426, TNC 430
Operand content
(dec or [bits])
1 5 0 0 0
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tnc 430 pa/mTnc 430 mTnc 426 cbTnc 430 caTnc 426 pbTnc 430 pa ... Show all

Table of Contents