Opening or erasing
screen mask for the
PLC window
6 – 266
7 7 7 7
Define the file names and path of the screen mask in one of the string
memories S0 to S15 or in an immediate string.
If no path name is specified, the path for the language indicated in
MP7230.3 (help files) is used.
Module 9210 Opening or erasing screen mask for the PLC window
With this module you can activate or erase the display in the large PLC
window.
Call:
PS
B/W/D/K/S<Erase no. of string memory/file name/PLC window>
0 to 7: String memory to S15
–1: Delete PLC window
CM
9210
PL
B/W/D
<Status / error>
0: Mask opened / mask erased
1: PLC window not yet ready again
-1: Error
If a faulty mask file was activated, an error message appears in the PLC
window.
Error message
COMMAND LIMITER ";" MISSING
UNKNOWN PARAMETER TOKEN
UNKNOWN COMMAND
STRING FORMAT ERROR
STRING NOT CLOSED
TOKEN TOO LONG (>32 CHAR)
PARAMETER INDEX MISSING
SOURCE FILE NOT OPENED
TEMPORARY FILE NOT OPENED
TOO FEW PARAMETERS
WRONG COMMAND PARAMETER
WRONG PARAMETER SWITCH
Meaning
End of command not found
Unknown code word
Unknown command
Impermissible format instruction
String end missing
Variable name is too long
Index is missing
Closing bracket "]" is missing
Source file is not opened
Temporary target file is not opened
Too few parameters for format
instruction
Parameter does not fit the format
Incorrect switch
HEIDENHAIN Technical Manual TNC 426, TNC 430