6.11.7 Temperature Monitoring

Internal
temperature of the
logic unit
Motor temperature
(only digital axes)
December 2001
The internal temperature of the logic unit is monitored constantly. At approx.
70 °C, the error message TNC OPERATING TEMP. EXCEEDED appears.
The internal temperature of the LE can be read with module 9133.
Module 9133 Internal temperature of the LE
Call:
PS
B/W/D/K <Code>
0: Internal temperature of the LE
CM
9133
PL
B/W/D
<Internal temperature of the LE>
Error recognition:
Marker
Value
Meaning
M4203
0
Internal temperature was read
1
Error code in W1022
W1022
2
Invalid code
To measure the motor temperature, a KTY 84 must be connected at pins 13
and 25 of X15 to X20, X62 to X64 and at X60. The temperature value is
ascertained at least once per second. The maximum permissible motor
temperature is taken from the motor table.
As soon as the given temperature is exceeded, the blinking error message
MOTOR TEMPERATURE <AXIS> TOO HIGH appears and the drives are automatically
switched off.
Module 9165 Sampling the current motor temperature
Appropriate measures can be taken before the motor reaches the maximum
temperature.
Call:
PS
B/W/D/K <Axis>
0 to 8 and 15 = Axes 1 to 9 and the spindle
CM
9165
PL
B/W/D
<Temperature>
Range: 0 to 255 °C
Error recognition:
Marker
Value
Meaning
M4203
0
No error
1
Control has no current controller
Monitoring Functions