4.3 List of Machine Parameters
4.3.1 Encoders and Machines
MP
Function and input
MP10
Active axes
Format:
Input:
MP20
Monitoring functions for the axes
Format:
Input:
MP20.0
Absolute position of the distance-coded reference marks
MP20.1
Amplitude of encoder signals
MP20.2
Edge separation of encoder signals
MP21
Monitoring functions for the spindle
Format:
Input:
MP21.0
No function
MP21.1
Amplitude of encoder signals
MP21.2
Edge separation of encoder signals
MP100
Designation of axes
Format:
Input:
MP100.0
Traverse range 1
MP100.1
Traverse range 2
MP100.2
Traverse range 3
MP110.0-8
Assignment of position encoder inputs to the axes
Input:
December 2001
%xxxxxxxxx
Bits 0 to 8 correspond to axes 1 to 9
0: Axis not active
1: Axis active
%xxxxxxxxx
Bits 0 to 8 correspond to axes 1 to 9
0: Monitoring not active
1: Monitoring active
%xx
Bit 0 – Spindle 1
0: Monitoring not active
1: Monitoring active
Bit 1 – Spindle 2
0: Monitoring not active
1: Monitoring active
XYZABCUVWxyzabcuvw-
Characters 1 to 9 correspond to axes 1 to 9
0: No position encoder input
1 to 6: Position encoder inputs X1 to X6
35 to 38: Position encoder inputs X35 to X38
List of Machine Parameters
Software
Page
version and
behavior
RESET
6 – 5
PLC
6 – 11
RUN
PLC
6 – 11
RUN
PLC
6 – 5,
6 – 28
RUN
6 – 16