Module 9135 Switch On 3-D Touch Probe - HEIDENHAIN TNC 426 PB/M Technical Manual

Table of Contents

Advertisement

6.15 Touch Probe
6 – 346
The following touch probes can be connected:
n
Touch trigger probes
• TS 120, TS 220: With cable connection for digitizing, tool setup and
measuring during machining
• TS 632: With infrared transmission for workpiece setup and
measurement during machining
• TT 130: For tool measurement
n
Measuring touch probe
For connecting the touch probes: (See "Mounting and Electrical Installation"
on page 3 – 5).
7 7 7 7
With MP6010 and MP6200, specify which touch probes are connected.
7 7 7 7
Make sure that the spindle is locked during the measuring process.
With FN18 you can read the current touch probe data.
MP6010
Selection of the touch probe
Input:
0: Touch probe with cable transmission
1: Touch probe with infrared transmission
MP6200
Selection of triggering or measuring touch probe (only with
"digitizing with measuring touch probe" option)
Input:
0: Triggering touch probe (e.g. TS 220)
1: Measuring touch probe
Note
The TNC 426/430 always emits a start signal when beginning a touch probe
cycle, meaning Module 9135 does not need to be used for HEIDENHAIN
touch probes.

Module 9135 Switch on 3-D touch probe

With Module 9135 you can switch on or retrigger certain 3-D touch probes. If
the touch probe is already switched on, the module call has no effect. If
M4056 is set and the touch probe does not provide a ready signal, the feed-
rate enabling (M4563) is reset.
Call:
CM
9135
Error recognition:
Marker
Value
Meaning
M4203
0
No error
1
Error in module run
HEIDENHAIN Technical Manual TNC 426, TNC 430