HEIDENHAIN TNC 426 PB/M Technical Manual page 886

Table of Contents

Advertisement

December 2001
MP4210.0-47 Setting a number in the PLC (D768 to D956)
Input:
-99 999.9999 to +99 999.9999
MP4220.0-4 Setting a number in the PLC (W960 to W968)
Input:
10 to 30 000
MP4230.0-31 Setting a number in the PLC (Module 9032)
Input:
-99 999.9999 to +99 999.9999
MP4231.0-31 Setting a number in the PLC (Module 9032)
Input:
-99 999.9999 to +99 999.9999
MP4310.0-6 Setting a number in the PLC
(W976 to W988, M4300 to M4411)
Input:
10 to 30 000
Module 9032 Read machine parameters
With this module you can read the value of the given machine parameter from
the active machine parameter file. The input value is transferred as a natural
number with the decimal point shifted by the number of possible decimal
places.
Only the value from the editable machine parameter file is read, not any value
modified in the run-time memory by PLC Module 9031.
For non-indexed machine parameters, zero must be transferred as the index.
Call only in a submit job.
Call:
PS
B/W/D/K
<MP number>
PS
B/W/D/K
<MP index>
CM
9032
PL
B/W/D
<MP value / Error code>
1: MP number does not exist
2: No separator (:)
3: MP value out of range
4: MP not found in file
5: No MP file found
6: Call was not in a submit job
7: MP is of the "string" type
8: No system memory
Data Transfer NC → PLC, PLC → NC
7 – 37