6.1.7 Lubrication Pulse

6 – 26
You can define the traverse distance for each axis after which the PLC
commands lubrication:
7 7 7 7
In MP4060.x you define the traverse distance at which the lubrication pulse
is to be output. The NC reports in W1056 when the entered distance in an
axis has been exceeded.
7 7 7 7
With W1058 you reset the distance counter to 0 after lubrication.
Note
After the TNC has been reset, the accumulated distance is reset.
MP4060.0-8 Traverse distance for lubrication of axes 1 to 9
Input:
0 to 99 999.9999 [mm] or [°]
W1056
Lubrication pulse: Value in MP4060
exceeded
Bits 0 to 8 represent axes 1 to 9
W1058
Resetting the accumulated distance
Bits 0 to 8 represent axes 1 to 9
HEIDENHAIN Technical Manual TNC 426, TNC 430