December 2001
Module 9032 Read machine parameters
With this module you can read the value of the given machine parameter from
the active machine parameter file. The input value is transferred as a natural
number with the decimal point shifted by the number of possible decimal
places.
Only the value from the editable machine parameter file is read, not any value
modified in the run-time memory by PLC Module 9031.
For non-indexed machine parameters, zero must be transferred as the index.
Call only in a submit job.
Call:
PS
B/W/D/K
<MP number>
PS
B/W/D/K
<MP index>
CM
9032
PL
B/W/D
<MP value / Error code>
1: MP number does not exist
2: No separator (:)
3: MP value out of range
4: MP not found in file
5: No MP file found
6: Call was not in a submit or spawn job
7: MP is of the "string" type
8: No system memory
Error recognition:
Marker
Value
Meaning
M4203
0
MP was read
1
MP could not be read from the table
Input and Output of Machine Parameters
4 – 9