6.13.32 Log

Entry
RESET
BERR
BREG
ERR
KEY
a
STIB
ON
OFF
BLINK
INFO
MAIN START
INFO
MAIN FILE DEL
INFO
MAIN HDD
INFO
MAIN CYCLES
a. STIB = control-in-operation symbol in the screen display
December 2001
The log serves as a troubleshooting aid. There are 2 MB of memory available
for this purpose.
All entries in the log are marked with the current date and time.
Display and Operation
Description
Powering up the control
Blinking error message
Register contents with a blinking error message
Error message
P: PLC error message with the line number in the PLC
error text file
N: NC error message with number
Key strokes
Control-in-operation on
Control-in-operation off
Control-in-operation symbol blinking
Control model and NC software
Faulty files on the hard disk, to be erased when
started up
Hard disk designation
Test results for fixed cycles and touch probe cycles
6 – 333