December 2001
Module 9184 Re-enabling groups of NC keys
With this module you cancel the effect of Module 9183.
Call:
PS
B/W/D/K <Key group code>
CM
9184
PL
B/W/D
<Error status>
0: Group of NC keys enabled
–1: Transferred value> maximum value
Error recognition:
Marker
Value
Meaning
M4203
0
Disabling was cancelled
1
Error code in W1022
W1022
2
Transferred parameter invalid
Module 9186 Call a soft-key function
With this module you can call certain soft-key functions in the machine
operating modes.
Do not call a new function until the previous one is completed. You can
interrogate this condition with Module 9187.
For a soft-key function to be simulated it must be displayed either in the
foreground or background operating mode. Otherwise the module has no
effect. Module 9187 reports the error.
Call:
PS
B/W/D/K <Number of the soft-key function>
0: INTERNAL STOP
1: M output
2: S output
3: PROBE FUNCTION
4: PASS OVER REFERENCE MARK
5: RESTORE POSITION
6: INCREMENTAL JOG
CM
9186
Error recognition:
Marker
Value
Meaning
M4203
0
Soft-key function was called
1
Error code in W1022
W1022
1
Parameter out of value range
28
Previous call not ended
Keystroke Simulation
6 – 341