3.7 Analog Input
Analog inputs
Inputs for Pt 100
thermistors
December 2001
The logic unit and the PLC input/output board PL 410B have analog inputs and
inputs for Pt 100 thermistors.
The PL 410B is available with and without analog inputs.
The current values of the inputs can be requested with Module 9003.
(See "Overview of Modules" on page 5 – 3).
Analog inputs (±10 V)
Logic unit
3
PL 405B
–
PL 410B
4
Voltage range:
Input resistance:
Resolution (W480, W482, W484): 100 mV
Resolution (Module 9003):
Internal value range:
Constant current:
Temperature range:
Resolution (W486, W488, W490): 0.5 °C
Resolution (Module 9003):
Internal value range:
Analog Input
Inputs for Pt 100
thermistors
3
–
4
–10 V to +10 V
> 250 kΩ
10 mV (LE)
100 mV (PL 410 B)
–100 to +100, at a resolution of 100 mV
-10 to +10, at a resolution of 10 mV
5 mA
0 °C to 100 °C
0.1 °C (LE)
0.5 °C (PL 410 B)
0 to 200, at a resolution of 0.5 °C
0 to 1000, at a resolution of 0.1 °C
3 – 47