HEIDENHAIN TNC 426 PB/M Technical Manual page 427

Table of Contents

Advertisement

December 2001
Test the P factor of the torque controller:
7 7 7 7
In MP10 reactivate the master and slave axes.
7 7 7 7
With the integrated oscilloscope, record the actual speed value V (N ACTL).
7 7 7 7
Increase the P factor in MP2910.x for the slave axis up to the oscillation
limit.
7 7 7 7
Enter in MP2910.x for the slave axis 50% of the resulting value.
MP2900.0-8 Tensioning torque between master and slave for master-
slave torque control (entry for the slave axis)
Input:
-100.00 to +100.00 [Nm]
MP2910.0-8 P factor of the torque controller for master-slave torque
control (entry for the slave axis)
Input:
0.00 to 999.99 [1/(Nm · min)]
MP2920.0-8 Factor for variable torque distribution for master-slave
torque control (entry for the slave axis)
Input:
0.000 to 100.000
1: Master and slave axes have identical motors
MP2930.0-8 Speed compensation ratio for master-slave torque control
(entry for the slave axis)
Input:
-100.00 to +100.00 [%]
Synchronized Axes
6 – 97

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tnc 430 pa/mTnc 430 mTnc 426 cbTnc 430 caTnc 426 pbTnc 430 pa ... Show all

Table of Contents