Function when MP1350.x = 0. This setting is used only to ensure
compatibility. Do not use for new installations.
If during automatic referencing the trip dog is not closed until it is in the
reference end position range, the contouring control will ignore this signal. It
is therefore necessary that there be at least two reference marks in the range
of the reference end position.
December 2001
Reference Marks
6 – 105