Soft keys within the TRACE function:
Soft key
Function
Select Markers/Inputs/Outputs/Timers/Counters for a logic
diagram.
Show logic diagram.
Search for text in statement list (TRACE IN CODE).
Show operand or accumulator contents in hexadecimal or
decimal.
Start and stop the dynamic display of the operand contents,
accumulator contents, and logic diagram with STOP
DISPLAY and START DISPLAY .
Start trace.
End trace.
Back to previous menu.
7 – 8
HEIDENHAIN Technical Manual TNC 426, TNC 430