Tool Measurement In A Tilted Coordinate System; Tool Breakage - HEIDENHAIN TNC 426 PB/M Technical Manual

Table of Contents

Advertisement

Tool measurement
in a tilted
coordinate system

Tool breakage

December 2001
7 7 7 7
If the tool is to be measured in a tilted position other than that in which the
tool touch probe was calibrated, set MP6500 bit 13 = 1.
MP6500
Tool measurement with TT 130
Format:
%xxxxxxxxxxxxx
Input:
Bit 13
0: Tool is measured in the tilt position in which the tool touch
probe was also calibrated
1: Tool is measured in another tilt position
Warning
If the tool is not measured in the same tilt position as that in which the tool
touch probe was calibrated, ensure that the tool is perpendicular to the
contact plate!
7 7 7 7
With MP6500 bits 5 and 6, specify whether the NC program should stop
when the breakage tolerance is exceeded. M4063 is always set when the
breakage tolerance is exceeded.
7 7 7 7
With bit 11, specify whether the result of "tool checking" measurement is
to be entered in the tool table.
MP6500
Tool measurement with TT 130
Format:
%xxxxxxxxxxxx
Input:
Bit 5 – NC stop during "tool checking"
0: The NC program is not stopped when the breaking tolerance
is exceeded
1: If the breakage tolerance is exceeded, the NC program is
stopped and the error message "tool broken" is displayed
Bit 6 – NC stop during "tool measurement"
0: The NC program is not stopped when the breakage tolerance
is exceeded
1: If the breakage tolerance is exceeded, the NC program is
stopped and the error message "touch point inaccessible" is
displayed
Bit 11 – "Tool checking" and changing in the tool routine
0: After "tool checking" the tool table is changed
1: After "tool checking" the tool table is not changed
Touch Probe
6 – 377

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tnc 430 pa/mTnc 430 mTnc 426 cbTnc 430 caTnc 426 pbTnc 430 pa ... Show all