You can select from the following values:
● Critical
System events are processed as of the severity level "Critical".
● Warning
System events are processed as of the severity level "Warning".
● Info
System events are processed as of the severity level "Info".
Procedure
Follow the steps below to configure the required level:
1. Select the required values from the drop-down lists of the second table column after the
client types.
2. Click the "Set Values" button.
5.4.8

SMTP client

Network monitoring with e-mails
The device provides the option of automatically sending an e-mail if an alarm event occurs (for
example to the network administrator). The e-mail contains the identification of the sending
device, a description of the cause of the alarm in plain language, and a time stamp. This allows
centralized network monitoring to be set up for networks with few nodes based on an e-mail
system. When an e-mail error message is received, the WBM can be started by the Internet
browser using the identification of the sender to read out further diagnostics information.
On this page, you can configure up to three SMTP servers and the corresponding e-mail
addresses.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 05/2017, C79000-G8976-C248-12
Configuring with Web Based Management
5.4 The "System" menu
171