cable downstream if-output
cable downstream if-output
To activate a downstream port on a cable interface and to generate either a standard modulated signal or
a test signal, use the cable downstream if-output command in cable interface configuration mode. To
disable all signal output on the intermediate frequency (IF) carrier and to shut down the interface, use
the no form of this command.
Syntax Description
continuous-wave
prbs
Defaults
The downstream interface is enabled for normal data use (cable downstream if-output).
Command Modes
Interface configuration (cable interface only)
Command History
Release
11.3 XA
12.0(7)XR2, 12.0(7)T,
12.(0)SC,12.1(2)EC1
Usage Guidelines
Typically, a downstream is configured to output a modulated signal, using the cable downstream if-
output command, allowing data transmissions to be sent over the HFC cable network. However, this
command can also be used to test the cable plant or to shut down the interface completely:
Cisco Broadband Cable Command Reference Guide
2-52
cable downstream if-output [continuous-wave | prbs]
no cable downstream if-output
Outputs an unmodulated carrier signal on the downstream, shutting down
normal data network operations.
Outputs a Pseudo Random Bit Stream (PRBS) test signal on the downstream,
shutting down normal data network operations.
Modification
This command was introduced.
This command was modified to support Annex A (EuroDOCSIS)
downstreams, and the continuous-wave and prbs options were added.
cable downstream if-output continuous-wave—Generates an unmodulated, continuous sine wave
on the downstream interface. You can use a spectrum analyzer to verify the frequency, amplitude,
and power of the wave. The test signal continues on the downstream until you resume normal
modulated operations using the cable downstream if-output command.
cable downstream if-output prbs—Generates a PRBS test signal on the downstream interface. You
can use a spectrum analyzer to verify the frequency, amplitude, and power of the wave. The test
signal continues on the downstream until you resume normal modulated operations using the cable
downstream if-output command.
no cable downstream if-output—Terminates all signal output and shuts down the downstream
interface. The interface remains shut down until you reactive the downstream using the cable
downstream if-output command.