Cisco SD2008T-NA Installation Manual

Cisco SD2008T-NA Installation Manual

Hardware installation guide
Hide thumbs Also See for SD2008T-NA:
Table of Contents

Advertisement

Cisco Nexus 2000 Series Hardware
Installation Guide
August 22, 2012
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
Text Part Number: OL-19013-05

Advertisement

Table of Contents

Troubleshooting

loading

Summary of Contents for Cisco SD2008T-NA

  • Page 1 Cisco Nexus 2000 Series Hardware Installation Guide August 22, 2012 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 Text Part Number: OL-19013-05...
  • Page 2 OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: www.cisco.com/go/trademarks.
  • Page 3: Table Of Contents

    Obtaining Documentation and Submitting a Service Request xviii Using a Fabric Extender with a Cisco Nexus 5000 Series Switch C H A P T E R Information About Using a Fabric Extender with a Cisco Nexus 5000 Series Switch Cisco Nexus 2248TP-E Chassis Ports...
  • Page 4 Using a Fabric Extender with a Cisco Nexus 7000 Series Switch C H A P T E R Information About Using a Fabric Extender with a Cisco Nexus 7000 Series Switch Cisco Nexus 2248TP-E FEX Ports for the Cisco Nexus 2248TP-E FEX...
  • Page 5 Installation Guidelines Required Tools and Equipment Unpacking and Inspecting the Cisco Nexus 2000 Series Fabric Extender Installing the Cisco Nexus 2000 Series Fabric Extender Chassis in a Cabinet or Rack Grounding the System Proper Grounding Guidelines Preventing Electrostatic Discharge Damage...
  • Page 6 Installing a Fan tray 3-21 Removing the Cisco Nexus 2000 Series Fabric Extender 3-22 Repacking the Cisco Nexus 2000 Series Fabric Extender for Return Shipment 3-22 Connecting a Cisco Nexus 2000 Series Fabric Extender C H A P T E R...
  • Page 7 Supported Power Cords and Plugs Power Cords Jumper Power Cord LEDs A P P E N D I X Chassis and Module LEDs for the Cisco Nexus 2000 Series Fabric Extenders Chassis and Module LED Descriptions Power Supply Status Port LEDs Ethernet Port LEDs...
  • Page 8 Contents Book Title viii 78-xxxxx-xx...
  • Page 9 Preface This preface describes the audience, organization, and conventions of the Cisco Nexus 2000 Series Hardware Installation Guide. It also provides information on how to obtain related documentation. This preface includes the following sections: • Audience, page ix • Organization, page ix •...
  • Page 10: Installation

    Provides troubleshooting information for the Cisco Nexus 2000 Hardware Components” Series Fabric Extenders. Appendix F, “Accessory Kit” Lists the accessory kit contents for the Cisco Nexus 2000 Series Fabric Extenders. Appendix G, “Site Preparation and Provides site preparation information for the Cisco Nexus 2000 Maintenance Records”...
  • Page 11 üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden. BEWAHREN SIE DIESE HINWEISE GUT AUF. Cisco Nexus 2000 Series Hardware Installation Guide OL-19013-05...
  • Page 12 Använd det nummer som finns i slutet av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna anordning. SPARA DESSA ANVISNINGAR Cisco Nexus 2000 Series Hardware Installation Guide OL-19013-05...
  • Page 13 Preface Cisco Nexus 2000 Series Hardware Installation Guide xiii OL-19013-05...
  • Page 14 Brug erklæringsnummeret efter hver advarsel for at finde oversættelsen i de oversatte advarsler, der fulgte med denne enhed. GEM DISSE ANVISNINGER Cisco Nexus 2000 Series Hardware Installation Guide OL-19013-05...
  • Page 15 Preface Cisco Nexus 2000 Series Hardware Installation Guide OL-19013-05...
  • Page 16: Related Documentation

    Preface Related Documentation Documentation for Cisco MDS 9200 Series Switches and Cisco Nexus 2000 Series Fabric Extenders is available at the following URL: http://www.cisco.com/en/US/products/ps9670/tsd_products_support_series_home.html The following are related Cisco MDS 9200 Series and Cisco Nexus 2000 Series Fabric Extender documents:...
  • Page 17: Troubleshooting Guide

    Cisco Nexus 2000 Series Hardware Installation Guide Cisco Nexus 5000 Series NX-OS Software Upgrade and Downgrade Guide, Release 4.2(1)N1(1) Regulatory Compliance and Safety Information for the Cisco Nexus 5000 Series Switches and Cisco Nexus 2000 Series Fabric Extenders Licensing Guide...
  • Page 18: Obtaining Documentation And Submitting A Service Request

    Obtaining Documentation and Submitting a Service Request For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What’s New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at: http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html...
  • Page 19: Cisco Nexus 2232Tm-10Ge, Cisco Nexusn2K-C2232Tm-E-10Ge

    The Cisco Nexus 2000 Series FEXs behave as remote I/O modules for a parent Cisco Nexus 5000 Series switch. The FEX is an extension of the parent Cisco Nexus switch fabric, with the FEX and the parent Cisco Nexus switch together forming a virtual modular system.
  • Page 20: Chassis

    Supported Transceivers and Cables, page 1-9 Chassis The Cisco Nexus 2248TP-E FEX chassis has a height of 1.72 inches (4.37 cm), a width of 17.3 inches (43.94 cm), and a depth of 17.7 inches (44.96 cm). It weighs 17.7 pounds (8.0 kg). Its one-rack-unit (1 RU) form factor takes up relatively little space, making it easy to incorporate into rack designs.
  • Page 21: Chassis

    5000 Series switch. Power Supplies The Cisco Nexus 2248TP-E FEX chassis has two bays for front-end AC or DC power supplies. This chassis is fully functional with one power supply, but you can install a second power supply for power redundancy.
  • Page 22: Power Supplies

    DC power supply with front-to-back airflow. Figure 1-6 shows a DC power supply with back-to-front airflow. Figure 1-3 AC Power Supply with Front-to-Back Airflow for the Cisco Nexus 2200 Platform Chassis Handle No black stripe (front-to-back airflow) FAIL (top) and OK (bottom) LEDs...
  • Page 23 Chapter 1 Using a Fabric Extender with a Cisco Nexus 5000 Series Switch Cisco Nexus 2248TP-E Figure 1-4 AC Power Supply with Back-to-Front Airflow for the Cisco Nexus 2200 Platform Chassis - 4 0 Handle Black stripe (back-to-front airflow) FAIL (top) and OK (bottom) LEDs...
  • Page 24 AC power receptacle Ejector latch You can order the Cisco Nexus 2248TP-E FEX with AC power supplies that have front-to-back or back-to-front airflow for cooling or DC power supplies that offer front-to-back airflow. The back-to-front airflow components have a black stripe on their front surface for easy visual identification.
  • Page 25: Fan Trays

    D-2. Fan Trays The Cisco Nexus 2248TP-E FEX has one fan tray that is hot swappable during operations. Depending on the arrangement of hot and cold aisles in your data center, you can order front-to-back airflow to position the front of the FEX chassis in a cold aisle or back-to-front airflow to position the back of the FEX chassis in a cold aisle.
  • Page 26: Fan Trays

    Chapter 1 Using a Fabric Extender with a Cisco Nexus 5000 Series Switch Cisco Nexus 2248TP-E Figure 1-8 Front-to-Back Airflow Fan Tray Components for the Cisco Nexus 2248TP-E and 2224TP FEXs Captive screws (2) Status LED No black stripe indicates front-to-back...
  • Page 27: Supported Transceivers And Cables

    The enhanced Small-Form-Factor Pluggable (SFP+) 10-Gigabit Ethernet transceiver is a bidirectional device with a transmitter and receiver. It has a 20-pin connector on the electrical interface and duplex LC connector on the optical interface. Currently, the Cisco Nexus 2248TP-E FEX supports the short-range SFP and long-range SFP transceiver.
  • Page 28: Supported Transceivers And Cables

    Supported Transceivers and Cables, page 1-16 Chassis The Cisco Nexus 2248TP FEX chassis has a height of 1.72 inches (4.37 cm), a width of 17.3 inches (43.94 cm), and a depth of 17.7 inches (44.96 cm). It weighs 17.7 pounds (8.0 kg). Its one-rack-unit (1 RU) form factor takes up relatively little space, making it easy to incorporate into rack designs.
  • Page 29: Cisco Nexus 2248Tp

    Chapter 1 Using a Fabric Extender with a Cisco Nexus 5000 Series Switch Cisco Nexus 2248TP Figure 1-10 Front View of the Cisco Nexus 2248TP Chassis Power supply Power supply (blank shown) Fan tray Status (top) and ID (bottom) LEDs...
  • Page 30: Power Supplies

    Nexus 5000 Series switch. Power Supplies The Cisco Nexus 2248TP FEX chassis has two bays for front-end AC or DC power supplies. This chassis is fully functional with one power supply, but you can install a second power supply for power redundancy.
  • Page 31 No black stripe (front-to-back airflow) OK (top) and FAULT (bottom) LEDs AC power receptacle Ejector latch Figure 1-13 AC Power Supply with Back-to-Front Airflow for the Cisco Nexus 2200 Platform Chassis - 4 0 Handle Black stripe (back-to-front airflow) FAULT (top) and OK (bottom) LEDs...
  • Page 32 No black stripe (front-to-back airflow) DC power receptacle You can order the Cisco Nexus 2248TP FEX with AC power supplies that have front-to-back or back-to-front airflow for cooling or DC power supplies that offer front-to-back airflow. The back-to-front airflow components have a black stripe on their front surface for easy visual identification.
  • Page 33: Fan Tray

    Cisco Nexus 2248TP Fan Tray The Cisco Nexus 2248TP (and 2224TP) FEX has one fan tray that is hot swappable during operations. Depending on the arrangement of hot and cold aisles in your data center, you can order front-to-back airflow to position the front of the FEX chassis in a cold aisle or back-to-front airflow to position the back of the FEX chassis in a cold aisle.
  • Page 34: Sfp Transceivers

    The enhanced Small-Form-Factor Pluggable (SFP+) 10-Gigabit Ethernet transceiver is a bidirectional device with a transmitter and receiver. It has a 20-pin connector on the electrical interface and duplex LC connector on the optical interface. Currently, the Cisco Nexus 2248TP FEX supports the short-range SFP and long-range SFP transceiver.
  • Page 35: Chassis

    • Chassis The Cisco Nexus 2232TM FEX chassis has a height of 1.72 inches (4.37 cm), a width of 17.3 inches (43.94 cm), and a depth of 17.7 inches (44.96 cm). It weighs 18.5 pounds (8.4 kg). Its one-rack-unit (1 RU) form factor takes up relatively little space, making it easy to incorporate into rack designs.
  • Page 36: Fan Tray

    Chapter 1 Using a Fabric Extender with a Cisco Nexus 5000 Series Switch Cisco Nexus 2232TM-10GE, Cisco NexusN2K-C2232TM-E-10GE You can order it with front-to-back or back-to-front air cooling, and AC or DC power supplies. If you are going to install the chassis with its front end facing the cold aisle, you must order the chassis with front-to-back airflow.
  • Page 37 10-Gigabit SFP+ ports (8) Ports The Cisco Nexus 2232TM FEX supports a total of 32 10-Gigabit Ethernet ports (SFP+) and 8 10-Gigabit Ethernet/FCoE uplinks (SFP+). SFP transceivers can also be plugged into the SFP+ cages to allow a 1-Gigabit downlink. The Cisco Nexus 2232TM-10GE provides two types of ports: ports for end-host attachment and uplink ports.
  • Page 38: Ports

    8 10-Gigabit SFP+ ports Power Supplies The Cisco Nexus 2232TM-10GE FEX chassis has two bays for front-end AC or DC power supplies. This chassis is fully functional with one power supply, but you can install a second power supply for power redundancy.
  • Page 39 D-2. Fan Trays The Cisco Nexus 2232TM-10GE FEX has one fan tray that is hot swappable during operations. Depending on whether there is a cold aisle in front of or in back of the chassis, you can order front-to-back airflow or back-to-front airflow for the fan tray and the power supplies in the same chassis.
  • Page 40: Fan Trays

    The enhanced Small-Form-Factor Pluggable (SFP+) 10-Gigabit Ethernet transceiver is a bidirectional device with a transmitter and receiver. It has a 20-pin connector on the electrical interface and duplex LC connector on the optical interface. Currently, the Cisco Nexus 2000 Series FEX supports the short-range SFP and long-range SFP transceiver.
  • Page 41: Cisco Nexus 2232Pp

    (10 meters) Cisco Nexus 2232PP The Cisco Nexus 2232PP is a stackable 1 RU 17.2 inch (45 cm) deep FEX that supports 32 10-Gigabit SFP+ host-facing (downlink) ports and 8 10-Gigabit SFP+ network-facing (uplink) ports. You can order it with front-to-back or back-to-front air cooling, which makes this FEX compatible with hot-aisle, cold aisle data center designs.
  • Page 42: Chassis

    Cisco Nexus 2232PP Chassis The Cisco Nexus 2232PP FEX chassis has a height of 1.72 inches (4.37 cm), a width of 17.3 inches (43.94 cm), and a depth of 17.7 inches (44.96 cm). It weighs 18.3 pounds (8.3 kg) and supports vertical orientation.
  • Page 43: Chassis

    (FCoE) ports (SFP+) and 8 10-Gigabit Ethernet/FCoE uplinks (SFP+). SFP transceivers can also be plugged into the SFP+ cages to allow a 1G downlink. The Cisco Nexus 2232PP provides two types of ports: ports for end-host attachments and uplink ports. Uplink ports are differentiated with yellow for connectivity to the upstream parent Cisco Nexus 5000 Series switch.
  • Page 44: Fan Trays

    Fan Trays The Cisco Nexus 2232PP FEX has one fan tray that is hot swappable during operations. Depending on whether there is a cold aisle in front of or in back of the chassis, you can order front-to-back airflow or back-to-front airflow for the fan tray and the power supplies in the same chassis.
  • Page 45: Fan Trays

    Chapter 1 Using a Fabric Extender with a Cisco Nexus 5000 Series Switch Cisco Nexus 2232PP Figure 1-25 Front-to-Back Airflow Fan Tray for the Cisco Nexus 2232PP FEX Captive screws (2) No black stripe indicates front-to-back airflow Handle Status LED...
  • Page 46: Supported Sfp+ Transceivers

    The enhanced Small-Form-Factor Pluggable (SFP+) 10-Gigabit Ethernet transceiver is a bidirectional device with a transmitter and receiver. It has a 20-pin connector on the electrical interface and duplex LC connector on the optical interface. Currently, the Cisco Nexus 2000 Series FEX supports the short-range SFP and long-range SFP transceiver.
  • Page 47: Cisco Nexus 2224Tp

    Cisco Nexus 2224TP The Cisco Nexus 2224TP is a stackable 1 RU FEX. This FEX is very similar to the Cisco Nexus 2248TP except that it has 24 100/1000BASE-T downlink ports, 2 SFP+ uplink ports and you can order it with front-to-back airflow or back-to-front airflow.
  • Page 48: Ports

    Series switch. Power Supplies The Cisco Nexus 2224TP FEX chassis has two bays for front-end AC or DC power supplies (the same power supplies used for the Cisco Nexus 2248TP). This chassis is fully functional with one power supply, but you can install a second power supply for power redundancy. The power supply is hot swappable during operations.
  • Page 49: Power Supplies

    Fan Tray The Cisco Nexus 2224TP FEX has one fan tray that is hot swappable during operations. Depending on whether there is a cold aisle in front of or in back of the chassis, you can order front-to-back airflow or back-to-front airflow for the fan tray and the power supplies in the same chassis.
  • Page 50: Supported Sfp+ Transceivers

    The enhanced Small-Form-Factor Pluggable (SFP+) 10-Gigabit Ethernet transceiver is a bidirectional device with a transmitter and receiver. It has a 20-pin connector on the electrical interface and duplex LC connector on the optical interface. Currently, the Cisco Nexus 2224TP FEX supports the short-range SFP and long-range SFP transceiver.
  • Page 51: Cisco Nexus 2148T

    Cisco Nexus 2148T Cisco Nexus 2148T The Cisco Nexus 2148T FEX is a 1 RU device that acts as a remote I/O module on the Cisco Nexus 5000 Series switch. All device configurations are managed on the switch and configuration information is downloaded through inband communication to the FEX.
  • Page 52 Power supply (two) Status (top) and ID (bottom) LEDs Fan tray (1) The rear of the Cisco Nexus 2148T FEX has 48 1-Gigabit Ethernet ports, 4 10-Gigabit Ethernet ports, and status and ID LEDs. Figure 1-30 identifies the components found on the rear of the Cisco Nexus 2148T FEX.
  • Page 53: Ports

    Cisco Nexus 2148T Ports Each port on the Cisco Nexus 2148T FEX is numbered, and groups of ports are numbered based on their function. The ports are numbered from top to bottom and left to right. Group 1 includes 48 1-Gigabit Ethernet data ports. Group 2 includes four 10-Gigabit Ethernet ports.
  • Page 54: Fan Tray

    Blank Power Supply Filler Panel Handle Ejector latch Fan Tray The Cisco Nexus 2148T FEX has one fan tray that has front-to-back airflow. Figure 1-34 shows the fan tray. The fan tray is hot-swappable as long as you replace it within 60 seconds.
  • Page 55: Supported Sfp Transceivers

    The enhanced Small-Form-Factor Pluggable (SFP+) 10-Gigabit Ethernet transceiver is a bidirectional device with a transmitter and receiver. It has a 20-pin connector on the electrical interface and duplex LC connector on the optical interface. Currently, the Cisco Nexus 2000 Series FEX supports the short-range SFP and long-range SFP transceiver.
  • Page 56 Chapter 1 Using a Fabric Extender with a Cisco Nexus 5000 Series Switch Cisco Nexus 2148T Table 1-22 Copper Cables Used with the Cisco Nexus 2148T FEX Model Description SFP-H10GB-CU7MA 10-Gigabit BASE-CU SFP+ Active Cable (7 meters) SFP-H10GB-CU10MA 10-Gigabit BASE-CU SFP+ Active Cable...
  • Page 57: Chapter 2 Using A Fabric Extender With A Cisco Nexus 7000 Series Switch

    I/O modules. Depending on which FEX model that you connect to the switch, the FEX provides top-of-the-rack connectivity for up to 48, 32, or 24 hosts, and it becomes an extension of the parent Cisco Nexus 7000 Series switch fabric, with the FEX and the switch becoming a virtual modular system. The FEX forwards all 100/1000 Ethernet or 1- and 10-Gigabit Ethernet traffic from the hosts to the switch over 10-Gbps uplinks.
  • Page 58: Cisco Nexus 2248Tp-E Fex

    (all of these components must either have a black stripe or all of the components must not have a black stripe). The front of the Cisco Nexus 2248TP-E FEX chassis has one or two power supplies, a fan tray, and two chassis LEDs as shown in Figure 2-1.
  • Page 59 Power supply (blank shown) Fan tray Status (top) and ID (bottom) LEDs The rear of the Cisco Nexus 2248TP-E FEX chassis has 48 100/1000 Ethernet downlink ports, four 10-Gigabit Ethernet uplink ports, an HDMI port, and LEDs, as shown in Figure 2-2.
  • Page 60: Ports For The Cisco Nexus 2248Tp-E Fex

    Power Supplies for the Cisco Nexus 2248TP-E FEX The Cisco Nexus 2200 Series FEX chassis have two slots for front-end AC or DC power supplies that have front-to-back or back-to-front airflow. These chassis are fully functional with one power supply, but you can install a second power supply for power redundancy.
  • Page 61 Figure 2-4 AC Power Supply with Front-to-Back Airflow for the Cisco Nexus 2200 Platform Handle No black stripe (front-to-back airflow)
  • Page 62 S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m Figure 2-5 DC Power Supply with Front-to-Back Airflow for the Cisco Nexus 2200 Platform Handle...
  • Page 63: Fan Tray For The Cisco Nexus 2248Tp-E Fex

    3-17. Fan Tray for the Cisco Nexus 2248TP-E FEX The Cisco Nexus 2224TP, 2248TP, and 2248TP-E FEXs use the same fan tray that you can order with either front-to-back airflow (N2K-C2248-FAN) or back-to-front airflow (N2K-C2248-FAN-B). The fan tray includes a status LED that indicates whether the module is operational. You can hot swap the fan tray during operations as described in the “Removing and Installing the Fan Tray”...
  • Page 64 Chapter 2 Using a Fabric Extender with a Cisco Nexus 7000 Series Switch Cisco Nexus 2248TP-E FEX S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m...
  • Page 65: Transceivers And Connectors Supported By The Cisco Nexus 2248Tp-E Fex

    The Cisco Nexus 2248TP-E FEX supports SFP+ Ethernet optical and copper transceivers and optical FEX Transceivers (FETs) for up to four fabric uplink connections to Cisco Nexus 7000 Series switches, and it supports RJ-45 connectors for up to 48 downlink connections to hosts. For each uplink cable, you must use the same transceiver on both ends.
  • Page 66 Chapter 2 Using a Fabric Extender with a Cisco Nexus 7000 Series Switch Cisco Nexus 2248TP-E FEX S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m...
  • Page 67: Cisco Nexus 2248Tp Fex

    (all of these components must either have a black stripe or all of the components must not have a black stripe). The front of the Cisco Nexus 2248TP FEX chassis has one or two power supplies, a fan tray, and two chassis LEDs as shown in Figure 2-13.
  • Page 68 Power supply (blank shown) Fan tray Status (top) and ID (bottom) LEDs The rear of the Cisco Nexus 2248TP-E FEX has 48 100/1000 Ethernet downlink ports, four 10-Gigabit Ethernet uplink ports, an HDMI port, and LEDs, as shown in Figure 2-14.
  • Page 69: Ports For The Cisco Nexus 2248Tp Fex

    Power Supplies for the Cisco Nexus 2248TP FEX The Cisco Nexus 2200 Platform FEX chassis have two slots for front-end AC or DC power supplies that have front-to-back or back-to-front airflow. These chassis are fully functional with one power supply, but you can install a second power supply for power redundancy.
  • Page 70: Fan Tray For The Cisco Nexus 2248Tp Fex

    3-17. Fan Tray for the Cisco Nexus 2248TP FEX The Cisco Nexus 2224TP, 2248TP, and 2248TP-E FEXs use the same fan tray that you can order with either front-to-back airflow (N2K-C2248-FAN) or back-to-front airflow (N2K-C2248-FAN-B). For information on this fan tray, see the “Fan Tray for the Cisco Nexus 2248TP-E FEX”...
  • Page 71: Cisco Nexus 2232Tm Fex

    The front of the Cisco Nexus 2232TM FEX chassis has one or two power supplies, a fan tray, and two LEDs as shown in Figure 2-16.
  • Page 72 Power supply (blank shown) Fan tray Status (top) and ID (bottom) LEDs The rear of the Cisco Nexus 2232TM FEX has 32 1- and 10-Gigabit Ethernet downlink ports, eight 10-Gigabit Ethernet uplink ports, an HDMI port, and two LEDs, as shown in Figure 2-22.
  • Page 73: Ports For The Cisco Nexus 2232Tm Fex

    Power Supplies for the Cisco Nexus 2232TM FEX The Cisco Nexus 2200 Platform FEX chassis have two slots for front-end AC or DC power supplies that have front-to-back or back-to-front airflow. These chassis are fully functional with one power supply, but you can install a second power supply for power redundancy.
  • Page 74: Fan Tray For The Cisco Nexus 2232Tm Fex

    3-17. Fan Tray for the Cisco Nexus 2232TM FEX The Cisco Nexus 2232PP and 2232TM FEX use the same fan tray, which you can order with either front-to-back airflow (N2K-C2248-FAN) or back-to-front airflow (N2K-C2248-FAN-B). The fan tray includes a status LED that indicates whether the module is operational. You can hot swap the fan tray during operations as described in the “Removing and Installing the Fan Tray”...
  • Page 75: Transceivers And Connectors Supported By The Cisco Nexus 2232Tm Fex

    Transceivers and Connectors Supported by the Cisco Nexus 2232TM FEX The Cisco Nexus 2232TM FEX supports SFP+ Ethernet optical and copper transceivers and optical FEX Transceivers (FETs) for up to eight fabric uplink connections to the following Cisco Nexus 7000 Series switch I/O modules: •...
  • Page 76: Cisco Nexus 2232Pp Fex

    Cisco Nexus 2232PP FEX The Cisco Nexus 2232PP FEX is a stackable 1- and 10-Gigabit FEX that has 32 1- and 10-Gbps Ethernet host-facing (downlink) SFP or SFP+ ports and eight 10-Gbps Ethernet and Fibre Channel over Ethernet (FCoE) network-facing (uplink) SFP+ or FET ports. It requires a 19-inch (48.26 cm) rack for its installation.
  • Page 77 If you are going to install the port side in the cold aisle, order back-to-front airflow for the fan trays and power supplies. The front of the Cisco Nexus 2232PP FEX chassis has one or two power supplies, a fan tray, and two LEDs as shown in Figure 2-21.
  • Page 78: Ports For The Cisco Nexus 2232Pp Fex

    Chapter 2 Using a Fabric Extender with a Cisco Nexus 7000 Series Switch Cisco Nexus 2232PP FEX S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m...
  • Page 79: Power Supplies For The Cisco Nexus 2232Pp Fex

    Power Supplies for the Cisco Nexus 2232PP FEX The Cisco Nexus 2200 Platform FEX chassis have two slots for front-end AC or DC power supplies that have front-to-back or back-to-front airflow. These chassis are fully functional with one power supply, but you can install a second power supply for power redundancy.
  • Page 80: Transceivers Supported By The Cisco Nexus 2232Pp Fex

    Transceivers Supported by the Cisco Nexus 2232PP FEX The Cisco Nexus 2232PP FEX supports SFP+ Ethernet optical and copper transceivers and optical FEX Transceivers (FETs) for up to eight fabric uplink connections to the following Cisco Nexus 7000 Series switch I/O modules: •...
  • Page 81: Cisco Nexus 2224Tp Fex

    The front of the Cisco Nexus 2224TP FEX chassis has one or two power supplies, a fan tray, and two LEDs as shown in Figure 2-24.
  • Page 82 Power supply (blank shown) Fan tray Status (top) and ID (bottom) LEDs The rear of the Cisco Nexus 2224TP FEX has 24 100/1000 BASE-T Ethernet downlink ports, two 10-Gigabit Ethernet uplink ports, an HDMI port, and LEDs, as shown in Figure 2-25.
  • Page 83: Ports For The Cisco Nexus 2224Tp Fex

    Power Supplies for the Cisco Nexus 2224TP FEX The Cisco Nexus 2200 Platform FEX chassis have two slots for front-end AC or DC power supplies that have front-to-back or back-to-front airflow. These chassis are fully functional with one power supply, but you can install a second power supply for power redundancy.
  • Page 84: Fan Tray For The Cisco Nexus 2224Tp Fex

    3-17. Fan Tray for the Cisco Nexus 2224TP FEX The Cisco Nexus 2224TP, 2248TP, and 2248TP-E FEXs use the same fan tray that you can order with either front-to-back airflow (N2K-C2248-FAN) or back-to-front airflow (N2K-C2248-FAN-B). For information on this fan tray, see the “Fan Tray for the Cisco Nexus 2248TP FEX”...
  • Page 85 Chapter 2 Using a Fabric Extender with a Cisco Nexus 7000 Series Switch Cisco Nexus 2224TP FEX Figure 2-11 on page 2-10 identifies the major features of the SFP+ copper transceiver and cable used for uplink connections. For the cable specifications that apply to these transceivers, see the “SFP+ Copper...
  • Page 86 Chapter 2 Using a Fabric Extender with a Cisco Nexus 7000 Series Switch Cisco Nexus 2224TP FEX S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m...
  • Page 87 C H A P T E R Installing a Cisco Nexus 2000 Series Fabric Extender This chapter describes how to install the Cisco Nexus 2000 Series Fabric Extenders (FEXs) and includes the following sections: • Preparing for Installation, page 3-2 Installing the Cisco Nexus 2000 Series Fabric Extender Chassis in a Cabinet or Rack, page 3-5 •...
  • Page 88: C H A P T E R 3 Installing A Cisco Nexus 2000 Series Fabric Extender

    Airflow Considerations Airflow through the Cisco Nexus 2000 Series FEX is from the front to the back or the back to the front. To ensure proper airflow, follow these guidelines: Position the chassis so that its air intake side (front side for front-to-back airflow or back side for •...
  • Page 89: Chassis Weight

    When lifting the system, follow these guidelines: Disconnect all power and external cables before lifting the system. • Have two people lift the system. The Cisco Nexus 2000 Series FEXs can weigh up to 18.5 pounds • (8.4 kg). Ensure that your footing is solid and the weight of the system is evenly distributed between your •...
  • Page 90: Required Tools And Equipment

    • Grounding cable (6 AWG recommended), sized according to local and national installation requirements; the required length depends on the proximity of the Cisco Nexus 2000 Series FEX to proper grounding facilities Crimping tool large enough to accommodate girth of lug •...
  • Page 91: Installing The Cisco Nexus 2000 Series Fabric Extender Chassis In A Cabinet Or Rack

    Installing the Cisco Nexus 2000 Series Fabric Extender Chassis in a Cabinet or Rack This section describes how to use the rack-mount kit provided with the device to install the Cisco Nexus 2000 Series FEX into a cabinet or rack that meets the requirements described in Appendix A, “Cabinet...
  • Page 92 Installing a Cisco Nexus 2000 Series Fabric Extender Installing the Cisco Nexus 2000 Series Fabric Extender Chassis in a Cabinet or Rack S e n d d o c u m e n t c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m...
  • Page 93 Installing a Cisco Nexus 2000 Series Fabric Extender Installing the Cisco Nexus 2000 Series Fabric Extender Chassis in a Cabinet or Rack S e n d d o c u m e n t c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m...
  • Page 94 Installing a Cisco Nexus 2000 Series Fabric Extender Installing the Cisco Nexus 2000 Series Fabric Extender Chassis in a Cabinet or Rack S e n d d o c u m e n t c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m...
  • Page 95: Grounding The System

    Chapter 3 Installing a Cisco Nexus 2000 Series Fabric Extender Grounding the System S e n d d o c u m e n t c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m...
  • Page 96: Preventing Electrostatic Discharge Damage

    Chapter 3 Installing a Cisco Nexus 2000 Series Fabric Extender Grounding the System S e n d d o c u m e n t c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m...
  • Page 97 ESD grounding straps are available with banana plugs, metal spring clips, or alligator clips. All • Cisco Nexus 2000 Series FEX chassis are equipped with a banana plug connector (identified by the ground symbol next to the connector) somewhere on the front panel. We recommend that you use a personal ESD grounding strap equipped with a banana plug.
  • Page 98 S e n d d o c u m e n t c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m Figure 3-5 shows how to attach the ESD wrist strap to the system ground lug screw for the Cisco Nexus 2000 Series FEX.
  • Page 99: Establishing The System Ground

    The system (NEBS) ground connection is required if this equipment is installed in a U.S. or European Central Office. • You do not need to power down the chassis because the Cisco Nexus 2000 Series FEX is equipped with AC-input power supplies. Required Tools and Equipment To connect the system ground, you need the following tools and materials: •...
  • Page 100: Grounding The Chassis

    The chassis has a grounding pad with two threaded M4 holes for attaching a grounding lug. Figure 3-6 shows the system ground location on the Cisco Nexus 2000 Series FEX. When installing or replacing the unit, the ground connection must always be made first and Warning disconnected last.
  • Page 101: Starting The Cisco Nexus 2000 Series Fabric Extender

    Do not connect the Ethernet port to the LAN until the initial device configuration has been performed. Note For instructions on configuring the device, see the Cisco Nexus 2000 Series Fabric Extender Software Configuration Guide. For instructions on connecting to the console port, see the “Connecting to the...
  • Page 102 Plug the power cable into the power receptacle on the power supply. Attach the other end of the power cable to the AC power source. If you are connecting cables to a Cisco Nexus 2148T power supply, flip the switch above the AC receptacle on the power supply to ON.
  • Page 103: Removing And Installing Components

    Removing an AC Power Supply If you are using the Cisco Nexus 2000 Series FEX with one power supply, removing the power supply Caution causes the device to shut down. If you are using two power supplies and you remove one of them, the device continues to operate.
  • Page 104: Installing An Ac Power Supply

    • thumb latch to the left and pull the panel out of the chassis. If you are removing a filler panel from a Cisco Nexus 2148T FEX, loosen its captive screw, and then • pull the panel out of the power supply bay.
  • Page 105: Removing A Dc Power Supply

    Secure the power supply to the chassis as follows: Step 4 If you are installing a Cisco Nexus 2248TP, 2232PP, or 2224TP FEX, make sure that the thumb latch • engages with the chassis so that the power supply is held in the slot.
  • Page 106: Removing And Installing The Fan Tray

    Chapter 3 Installing a Cisco Nexus 2000 Series Fabric Extender Removing and Installing Components S e n d d o c u m e n t c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m...
  • Page 107 S e n d d o c u m e n t c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m Figure 3-8 shows how to remove and install a fan tray for the Cisco Nexus 2000 Series FEX. Figure 3-8...
  • Page 108: Removing The Cisco Nexus 2000 Series Fabric Extender

    Repacking the Cisco Nexus 2000 Series Fabric Extender for Return Shipment If you need to return the Cisco Nexus 2000 Series FEX, remove the device from the rack by following the steps in the “Removing the Cisco Nexus 2000 Series Fabric Extender” section on page 3-22, and repack it for shipment.
  • Page 109: Chapter 4 Connecting A Cisco Nexus 2000 Series Fabric Extender

    Connecting a Cisco Nexus 2000 Series Fabric Extender This chapter describes how to connect the ports on a Cisco Nexus 2000 Series Fabric Extender (FEX). Caution When running power and data cables in overhead or subfloor cable trays, we strongly recommend that you have power cables and other potential noise sources as far away as practical from network cabling that terminates on Cisco equipment.
  • Page 110: Preparing For Network Connections

    This section describes how to connect a 10-Gigabit Ethernet port to a host. There are four network facing 10-Gigabit Ethernet ports for the Cisco Nexus 2248GV, 2148T, and 2248TP, eight for the Cisco Nexus 2232TM, 2232PP, and two on the Cisco Nexus 2224TP. An SFP+ transceiver is used to connect to a 10-Gigabit Ethernet port.
  • Page 111: Installing An Sfp+ Transceiver

    Chapter 4 Connecting a Cisco Nexus 2000 Series Fabric Extender Connecting to a 10-Gigabit Ethernet Port Installing an SFP+ Transceiver To install an SFP+ transceiver, follow these steps: Step 1 Attach an ESD-preventive wrist strap and follow its instructions for use.
  • Page 112: Removing And Installing Cables Into Sfp+ Transceivers

    Chapter 4 Connecting a Cisco Nexus 2000 Series Fabric Extender Connecting to a 10-Gigabit Ethernet Port If you have difficulty removing a bale clasp SFP+ transceiver, you should reseat it by returning Note the bale clasp to the up position. Press the SFP+ transceiver inward and upward into the cage.
  • Page 113: Removing A Cable From An Sfp+ Transceiver

    If the cable does not install easily, ensure that it is correctly positioned before continuing. Caution For instructions on verifying connectivity, see the Cisco Nexus 2000 Series Fabric Extender Software Configuration Guide. Cisco Nexus 2000 Series Hardware Installation Guide...
  • Page 114: Maintaining Sfp+ Transceivers And Cables

    Chapter 4 Connecting a Cisco Nexus 2000 Series Fabric Extender Connecting to a 10-Gigabit Ethernet Port Maintaining SFP+ Transceivers and Cables You must keep SFP+ transceivers clean and dust free to maintain high signal accuracy and prevent damage to the connectors. Attenuation (loss of light) is increased by contamination and should be below 0.35 dB.
  • Page 115: Appendix

    Standard 19-in. (48.3 cm) (four-post EIA cabinet or rack, with mounting rails that conform to • English universal hole spacing per section 1 of ANSI/EIA-310-D-1992). See the “Requirements Specific to Perforated Cabinets” section on page A-2. Cisco Nexus 2000 Series Hardware Installation Guide OL-19013-05...
  • Page 116: Requirements Specific To Perforated Cabinets

    Cabinet and Rack Installation Cabinet and Rack Requirements The cabinet or rack must also meet the following requirements: The minimum vertical rack space per Cisco Nexus 2000 Series FEX chassis must be one RU (rack • units), equal to 1.75 inches (4.4 cm).
  • Page 117: Appendix A Cabinet And Rack Installation

    To help with cable management, you might want to allow additional space in the rack above and below the chassis to make it easier to route as many as 56 fiber or copper cables through the rack. Cisco Nexus 2000 Series Hardware Installation Guide OL-19013-05...
  • Page 118 Appendix A Cabinet and Rack Installation Cable Management Guidelines Cisco Nexus 2000 Series Hardware Installation Guide OL-19013-05...
  • Page 119: Appendix

    A P P E N D I X Technical Specifications This appendix describes the technical specifications for the Cisco Nexus 2000 Series Fabric Extenders (FEXs) and includes the following sections: Power Specifications, page B-1 • • Environmental Specifications, page B-4 •...
  • Page 120 Appendix B Technical Specifications Power Specifications Table B-1 Power Specifications for the Cisco Nexus 2000 Series Power Supply N2K-PAC-200 N2K-PAC-400W N2200-PDC-350W-B N2K-PAC-400W-B Cisco Nexus 2000 Series N2K-PDC-400W FEXs Cisco Nexus Cisco Nexus 2248TP-E, Cisco Nexus 2248TP-E, 2148T 2248TP, 2232PP, 2224TP, and...
  • Page 121: Appendix B Technical Specification

    Appendix B Technical Specifications Power Specifications Table B-1 Power Specifications for the Cisco Nexus 2000 Series (continued) Power Supply N2K-PAC-200 N2K-PAC-400W N2200-PDC-350W-B N2K-PAC-400W-B Cisco Nexus 2000 Series N2K-PDC-400W Output Current 11.5 A/16.7 A Cisco Nexus 2248TP-E: Cisco Nexus 2248TP-E: (typical/maxim...
  • Page 122: Environmental Specifications

    Appendix B Technical Specifications Environmental Specifications Table B-1 Power Specifications for the Cisco Nexus 2000 Series (continued) Power Supply N2K-PAC-200 N2K-PAC-400W N2200-PDC-350W-B N2K-PAC-400W-B Cisco Nexus 2000 Series N2K-PDC-400W Power Cord 3 A@100 Vin / 6 A@100 Vin / 3 A@240 Vin...
  • Page 123: Physical Specifications

    Altitude 0 to 10000 ft (0 to 3000 m) The Cisco Nexus 2232PP, 2232TM, and the Cisco Nexus 2248TP-ETP FEXs can operate from 0 to 40°C ambient temperature in a horizontal or vertical rack mount configuration. They can withstand a nonoperational temperature of –25 to 70°C altitude of 10 to 90 percent noncondensing.
  • Page 124: Transceiver Specifications

    Appendix B Technical Specifications Transceiver Specifications Transceiver Specifications This section describes the transceiver specifications for the Cisco Nexus 2000 Series FEX. This section includes the following topics: SFP+ Optical Transceiver Specifications, page B-6 • SFP+ Optical Transceiver Specifications This section provides the general and environmental specifications for the SFP+ transceivers used with optical cables.
  • Page 125: Sfp+ Copper Transceiver Specifications

    32.8 feet (10 meters) Airflow Optimization Accessories This section describes the airflow optimization accessories for the Cisco Nexus 2000 Series FEX. For the details of the Cisco Nexus airflow extension sleeve and the Cisco Nexus airflow vent, see Table B-7.
  • Page 126 Appendix B Technical Specifications Airflow Optimization Accessories Cisco Nexus 2000 Series Hardware Installation Guide OL-19013-05...
  • Page 127: Appendix

    Only the regular power cords or jumper power cords provided with the device are supported. Note Table C-1 lists the AC power cords for the Cisco Nexus 2000 Series FEX and provides their lengths in feet and meters. Table C-1...
  • Page 128: Supported Power Cords And Plugs

    Appendix C Cable and Port Specifications Supported Power Cords and Plugs Table C-1 AC Power Cords for the Cisco Nexus 2000 Series FEX (continued) Length Power Cord Reference Description Feet Meters Illustration SFS-250V-10A-CN Figure C-3 Power Cord, 250 VAC 10 A GB 2009 Plug...
  • Page 129 Appendix C Cable and Port Specifications Supported Power Cords and Plugs Table C-1 AC Power Cords for the Cisco Nexus 2000 Series FEX (continued) Length Power Cord Reference Description Feet Meters Illustration CAB-C13-C14-2M(=) Power Cord Jumper, C13-C14 Connectors, 2 Meter Length...
  • Page 130 CAB-9K10A-EU Cordset rating: 10A/16 A, 250 V Length: 8 ft 2 in. (2.5 m) Plug: M2511 Connector: VSCC15 Figure C-5 SFS-250V-10A-ID Cordset rating 16A, 250V Plug: (2500mm) EL 208 Connector: EL 701 Cisco Nexus 2000 Series Hardware Installation Guide OL-19013-05...
  • Page 131 I/3G C15M (CEI 23-16) (EN60320/C15 ) Figure C-8 CAB-9K10A-SW Cordset rating: 10 A, 250 V/500 V MAX Length: 2500mm Connector: EL 701C Plug: EL 210 (EN 60320/C15) (BS 1363A) 13 AMP fuse Cisco Nexus 2000 Series Hardware Installation Guide OL-19013-05...
  • Page 132 Cordset rating 13A, 250V (6.6 feet) (79±2m) Connector: Plug: EL 701 EL312MoldedTwistlock (IEC60320/C13) (NEMA L6-20) Figure C-11 CAB-N5K6A-NA Cordset rating: 10 A, 250 V Length: 8.2 ft Plug: NEMA 6-15P Connector: IEC60320/C13 Cisco Nexus 2000 Series Hardware Installation Guide OL-19013-05...
  • Page 133 NEMA 5-15P IEC60320/C15 Figure C-13 CAB-C13-CBN Cordset rating 10A, 250V (686mm) Connector: Plug: HS10S SS10A Figure C-14 CAB-IND-10A Cordset rating 10A, 250V (8.2 feet) (2.5m) Plug: Connector EL 208B (IS 6538-1971) EL701B (IEC60320/C13) Cisco Nexus 2000 Series Hardware Installation Guide OL-19013-05...
  • Page 134: Power Cords

    Cisco Nexus 2000 Series FEX. The plug plugs into the Cisco Nexus 2000 Series FEX power supply, while the connector plugs into the receptacle of a power distribution unit for a cabinet.
  • Page 135 Appendix C Cable and Port Specifications Jumper Power Cord Figure C-16 CAB-C13-C14-JMPR, Jumper Power Cord Cordset rating 10A, 250V (686mm) Connector: Plug: HS10S SS10A Cisco Nexus 2000 Series Hardware Installation Guide OL-19013-05...
  • Page 136 Appendix C Cable and Port Specifications Jumper Power Cord Cisco Nexus 2000 Series Hardware Installation Guide C-10 OL-19013-05...
  • Page 137: Appendix

    A P P E N D I X LEDs This appendix describes the conditions indicated by the chassis and module LEDs on the Cisco Nexus 2000 Series Fabric Extenders (FEXs). This appendix includes the following sections: • Chassis and Module LEDs for the Cisco Nexus 2000 Series Fabric Extenders, page D-1 •...
  • Page 138: Chassis And Module Led Descriptions

    Appendix D LEDs Chassis and Module LEDs for the Cisco Nexus 2000 Series Fabric Extenders Chassis and Module LED Descriptions Table D-1 describes the chassis LEDs for the Cisco Nexus 2000 Series FEXs. Table D-1 LEDs for the Cisco Nexus 2000 Series FEXs...
  • Page 139: Power Supply Status

    “Power Supply Status” section on page D-3. Power Supply Status This section describes the power supply LED indicators for the Cisco Nexus 2000 Series FEXs. Table D-2 describes the status indicated by the Cisco Nexus 2248TP-ETP, 2232PP, and 2224TP power supply LEDs.
  • Page 140: Port Leds

    Appendix D LEDs Port LEDs Table D-3 Power Supply LED Indicators for the Cisco Nexus 2148T (continued) Condition INPUT OK LED Status (Green) OUTPUT OK LED Status (Red) Power supply warning events where the Blinking power supply continues to operate...
  • Page 141 Administrative disabled AMBER_ON Depending on the product you look at, the LED could be off, or solid amber Link Up, GREEN_ON Blinks based on network activity port in STP forwarding state Cisco Nexus 2000 Series Fabric Extenders Hardware Installation Guide OL-19013-05...
  • Page 142 Appendix D LEDs Port LEDs Cisco Nexus 2000 Series Fabric Extenders Hardware Installation Guide OL-19013-05...
  • Page 143: Appendix

    A P P E N D I X Troubleshooting Hardware Components This chapter describes how to identify and resolve problems that might occur with the hardware components of the Cisco Nexus 2000 Series Fabric Extender (FEX). It includes the following sections: Overview, page E-1 •...
  • Page 144: Device Hardware Guidelines

    Power supplies are supplying power to the system. Fan trays are operating normally. • The system software boots successfully. See the Cisco Nexus 2000 Series Fabric Extender Software • Configuration Guide for information about booting the system and initial configuration task.
  • Page 145: Contacting Customer Service

    Maintenance agreement or warranty information • Brief description of the problem • Brief explanation of the steps that you have already taken to isolate and resolve the problem • To contact customer service, go to http://www.cisco.com/en/US/support/index.html Cisco Nexus 2000 Series Hardware Installation Guide OL-19013-05...
  • Page 146 Appendix E Troubleshooting Hardware Components Contacting Customer Service Cisco Nexus 2000 Series Hardware Installation Guide OL-19013-05...
  • Page 147: Appendix

    A P P E N D I X Accessory Kit This appendix lists the accessory kit contents for the Cisco Nexus 2000 Series Fabric Extenders (FEXs) . This appendix includes the following sections: Accessory Kit for Cisco Nexus 2248TP-E, 2224TP, 2232PP, 2248TP, 2232TM, and 2148T, page F-5 •...
  • Page 148 Appendix F Accessory Kit Accessory Kit for Cisco Nexus 2248TP-E, 2224TP, 2232PP, 2248TP, 2232TM, and 2148T Book Title OL-19013-05...
  • Page 149: Appendix

    A P P E N D I X Site Preparation and Maintenance Records This appendix includes the following records to use when installing the Cisco Nexus 2000 Series Fabric Extender (FEX): Site Preparation Checklist, page G-1 • • Contact and Site Information, page G-3 •...
  • Page 150 Distance limitations for signaling • Site wiring • levels • 1. Verify that the power supply installed in the chassis has a dedicated AC source circuit. 2. UPS = uninterruptible power supply. Cisco Nexus 2000 Series Hardware Installation Guide OL-19013-05...
  • Page 151: Contact And Site Information

    G-2) to record contact and site information. Table G-2 Contact and Site Information Contact person Contact phone Contact e-mail Building/site name Data center location Floor location Address (line 1) Address (line 2) City State Zip code Country Cisco Nexus 2000 Series Hardware Installation Guide OL-19013-05...
  • Page 152: Chassis And Module Information

    IP broadcast address Gateway/router address DNS address Modem telephone number Table G-4 Module Information Slot Module Type Module Serial Number Notes Supervisor Note The supervisor module and the interface module are not removable. Cisco Nexus 2000 Series Hardware Installation Guide OL-19013-05...
  • Page 153: I N D E X

    Cisco Nexus 2200 Platform 1-4, 1-5, 1-6, 1-12, 1-13 ports 1-19, 1-25, 2-22 Cisco Nexus 2224TP 1-30 power supply 1-25, 2-23 Cisco Nexus 2232PP 1-25 transceivers 1-22, 1-28, 2-24 Cisco Nexus 2248TP 1-3, 1-12 Cisco Nexus 2000 Series Hardware Installation Guide IN-1 OL-19013-05...
  • Page 154 1-29, 2-25 Cisco Nexus 2248TP-E FET transceivers 2-28 grounding 3-14 ports 1-30, 2-27 installation power redundancy 2-25 guidelines power supply 1-30, 2-18, 2-27, 2-28 installing in a rack (procedure) transceivers 1-32, 2-28 Cisco Nexus 2000 Series Hardware Installation Guide IN-2 OL-19013-05...
  • Page 155 1-3, 1-12, 2-13 Ethernet LEDs power supply 1-3, 1-12, 2-13 description transceivers 1-9, 1-16, 2-14 Ethernet ports Cisco Nexus 2248TP-E connecting chassis expansion modules fan tray specifications features FET transceivers optical uplink transceivers Cisco Nexus 2000 Series Hardware Installation Guide IN-3 OL-19013-05...
  • Page 156 Cisco Nexus 2148T 1-33 Cisco Nexus 2224TP 1-29 Cisco Nexus 2232PP 1-24 Cisco Nexus 2248TP 1-2, 1-10, 2-11 Cisco Nexus 2248TP-E maintenance records considerations network, connecting grounding network connections Cisco Nexus 2000 Series Hardware Installation Guide IN-4 OL-19013-05...
  • Page 157: Physical Specifications

    Cisco Nexus 2232PP 1-19, 1-25, 2-22 transceivers 2-19 Cisco Nexus 2232TM 2-17 Nexus 2248TP Cisco Nexus 2248TP 1-3, 1-12, 2-13 chassis 1-2, 1-10, 2-2, 2-11 Cisco Nexus 2248TP-E copper interface cables 1-9, 1-17 Cisco Nexus 2000 Series Hardware Installation Guide IN-5 OL-19013-05...
  • Page 158 Small-Form-Factor Pluggable transceivers. See SFP options transceivers unpacking the switch specifications environmental expansion modules physical rack starting the FEX 3-15 chimney type, considerations switch installation open equipment required requirements guidelines solid walled screw torques rack-mount Cisco Nexus 2000 Series Hardware Installation Guide IN-6 OL-19013-05...
  • Page 159 1-9, 1-16, 2-14, 2-28 Cisco Nexus 2248TP-E 2-9, 2-14 Cisco Nexus 2224TP 2-28 Cisco Nexus 2232PP 2-24 Cisco Nexus 2232TM 2-19 replacing transceivers, supported SFPs. See SFP transceivers troubleshooting best practices Cisco Nexus 2000 Series Hardware Installation Guide IN-7 OL-19013-05...
  • Page 160 Index Cisco Nexus 2000 Series Hardware Installation Guide IN-8 OL-19013-05...