Configure Login mode

Login mode allows the user to log into the device through the serial port.
To change the configuration to match the serial configuration of the device to which you want to
connect:
  Web
1. Log into the IX10 WebUI as a user with Admin access.
2. On the menu, click System. Under Configuration, click Serial Configuration.
The Serial Configuration page is displayed.
Note
You can also configure the serial port by using Device Configuration > Serial. Changes
made by using either Device Configuration or Serial Configuration will be reflected in both.
3. Click the name of the port that you want to configure.
The serial port is enabled by default. To disable, toggle off Enable.
4. For Mode, select Login. This is the default.
5. (Optional) For Label, enter a label that will be used when referring to this port.
6. For Signalling, select the electrical signaling interface type used on this serial port:
RS-232
n
RS-485
n
l
The default is RS-232.
IX10 User Guide
Enable Termination if you want to enable electrical termination on this serial port.
Configure Login mode
163