RM0033
If the DMEIFx or the FEIFx flag is set due to an overrun or underrun condition, the faulty
stream is not automatically disabled and it is up to the software to disable or not the stream
by resetting the EN bit in the DMA_SxCR register. This is because there is no data loss
when this kind of errors occur.
When the stream's error interrupt flag (TEIF, FEIF, DMEIF) in the DMA_LISR or DMA_HISR
register is set, an interrupt is generated if the corresponding interrupt enable bit (TEIE,
FEIE, DMIE) in the DMA_SxCR or DMA_SxFCR register is set.
Note:
When a FIFO overrun or underrun condition occurs, the data are not lost because the
peripheral request is not acknowledged by the stream until the overrun or underrun
condition is cleared. If this acknowledge takes too much time, the peripheral itself may
detect an overrun or underrun condition of its internal buffer and data might be lost.
9.4
DMA interrupts
For each DMA stream, an interrupt can be produced on the following events:
•
Half-transfer reached
•
Transfer complete
•
Transfer error
•
Fifo error (overrun, underrun or FIFO level error)
•
Direct mode error
Separate interrupt enable control bits are available for flexibility as shown in
Half-transfer
Transfer complete
Transfer error
FIFO overrun/underrun
Direct mode error
Note:
Before setting an Enable control bit to '1', the corresponding event flag should be cleared,
otherwise an interrupt is immediately generated.
Table 30. DMA interrupt requests
Interrupt event
RM0033 Rev 9
Event flag
HTIF
TCIF
TEIF
FEIF
DMEIF
DMA controller (DMA)
Table
30.
Enable control bit
HTIE
TCIE
TEIE
FEIE
DMEIE